Télécharger Imprimer la page

Virutex CR94D Mode D'emploi page 7

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
(C) to adjust the rabetting height as indicated in (Fig. 7).
Tighten the securing knobs (D).
8. DIRECTION OF ADVANCE
When making the slots, it is vital that the direction of
advance of the machine be the same as the direction
of rotation of the bit (Fig. 9).
9. CHANGING THE BIT
Loosen the screws (F) and displace the guides (E)
outwards. Loosen screw (G) using a 4 mm key and the
service keys indicated in (Fig. 5 and Fig. 10). Replace
the bit, adjust the guides (E) to the size of the new bit,
and repeat the steps in reverse order to secure it.
10. JOINTS
The use of PVC and THERMOMELTABLE RUBBER joints
is recommended due to their excellent resistance to
weathering and their good insulation properties in both
hot and cold climates. In addition, they considerably
improve sound insulation against outside noise.
Types of PVC joints:
Profile
1204040 N9P
1201039 N10P
1204038 N11P
1204037 PL10P
1204036 PL11P
1204041 FP
Types of thermomeltable rubber joints:
Profile
1204049 N9GT
1204048 N10GT
1204047 N11GT
1204050 FGT
Each type of joint necessitates the use of the correct
bit, depending on the depth required.
In order to place the joints in the slots easily, it is
recommended that JOINT ROLLERS be used (see table).
JOINT
JOINT
MODEL
STOCK
N9P
1204040
N10P
1204039
N11P
1204038
PL10P
1204037
PL11P
1204036
FP
1204041
PP
1204042
N9GT
1204049
N10GT
1204048
N11GT
1204047
FGT
1204050
SLOT
MIN.
ROLLER
N.SIZE
RABBET
STOCK
8x3.5
10 mm
1850037
10x3.5
10 mm
1850037
10x4
11 mm
1850047
8x3.5
10 mm
1850037
8x3.5
11 mm
1850047
6x3.5
------
1850036
8x3.5
------
--------
8x3.5
9 mm
1850037
10x3.5
10 mm
1850037
10x3.5
11 mm
1850047
6x3.5
------
1850036
11. MAINTENANCE BRUSHES AND COLLECTOR
Disconnect the machine from the mains
before performing any maintenance
operations.
Remove the screws (H) from the cap, take it off and
the brushes will appear in their housing (Fig. 11).
Lift the springs (I) which hold them and replace with
new original VIRUTEX brushes, ensuring that they slide
smoothly through the guides (Fig. 12).
Reassemble as indicated.
We recommend running the machine for 15 minutes
after changing the brushes.
If the collector shows signs of burning or wear and
tear, we recommend bringing it to a VIRUTEX technical
service centre for repair. Never use emery paper for
this purpose.
Always keep the cable and socket in good repair.
12. NOISE AND VIBRATIONS LEVEL
The noise and vibration levels of this device have been
measured in accordance with European standard EN
60745-1 and serve as a basis for comparison with other
machines with similar applications.
The indicated vibration level has been determined for
the device's main applications and may be used as an
initial value for evaluating the risk presented by expo-
sure to vibrations. However, vibrations may reach levels
that are quite different from the declared value under
other application conditions, with other tools or with
insufficient maintenance of the electrical device or its
accessories, reaching a much higher value as a result
of the work cycle or the manner in which the electrical
device is used.
Therefore, it is necessary to establish safety measures
to protect the user from the effects of vibrations,
such as maintaining both the device and its tools in
perfect condition and organising the duration of work
cycles (such as operating times when the machine is
subjected to loads, and operating times when working
with no-load, in effect, not in use, as reducing the
latter may have a considerable effect upon the overall
exposure value).
13. GUARANTEE
All VIRUTEX power tools are guaranteed for 12 months
from the date of purchase, excluding any damage
which is a result of incorrect use or of natural wear
and tear on the machine.
All repairs should be carried out by the official VIRUTEX
technical assistance service.
7

Publicité

loading