Cleaning the filter in a dishwasher:
− Use a customary dishwasher detergent
− Do not put the saturated grease filters together with
crockery in the dishwasher
− Select a programme with a low temperature
− After cleaning allow the filter to drain.

When cleaning in a dishwasher the filter may
discolour as a result of the salt content. This
does not affect its operation.
Replacing the grease filters
− Before replacing the grease filter, clean the edges of
the part in the cooker hood in which the filter is placed.
− After cleaning the grease filter, replace the monoblock
filter in the grease filters.
− Replace the grease filters on the bottom plate.
− Close the bottom plate again.

Do not operate the unit without the grease
filters and monoblock filters

You can obtain a new grease filter from a dealer
or the Novy website. Article number grease
filter: 230.020 (2x).
Resetting the cleaning indicator
When you replace the grease filter after cleaning,all you
have to do is press the [+] and [-] keys simultaneously for
5 seconds to reset the replacement indicator.
If you do not do this, the orange indicator lights up when
the camera is turned on.
3.3 Monoblock filters
In each grease filter there are 2 half round black monoblock
filters. Only use the Novy Monoblock recirculation filter in
the cooker hood.
Replacement indicator monoblock filter
Indication: orange indicator lamp starts burning
After a fixed period of time, an orange light on the unit
indicates that the monoblock recirculation filter needs to
be changed.
Access to the monoblock filters
Open the bottom plate by pulling it open on the front
side with 2 hands in a downward movement.
The 2 grease filters are lying on the bottom plate. Take
the grease filters from the hood.
Remove the Monoblock recirculation filter

In each grease filter there are 2 half round black
monoblock filters. Take the 2 half round mono-
block filters from the aluminium grease filter!
Replacing the monoblock filter
Replace the new monoblock filter in the grease filters,
and replace the grease filters on the bottom plate.

Do not operate the unit without the grease
filters and monoblock filters
Resetting the replacement indicator
When you replace the new monoblock filters, all you
have to do is press the [+] and [-] keys simultaneously for
5 seconds to reset the replacement indicator.
If you do not do this, the orange indicator lights up when
the camera is turned on.

You can obtain a new monoblock filter from
specialist retailers or via the Novy website. Arti-
cle number monoblock filter: 230060