BML SL1-ALZ _ -U_ ZZ- _ U1L - _ _ _ _
Absolute magnetic encoder system
7
IO-Link Smart Sensor Profile Ed. 2 (BML SL1-ALZ1-UE/MZZ-_U1L-...) (continued)
7.4
System commands
Different commands have been implemented in the BML
which can be reached via the parameter System
Command on Index 2, Subindex 0. If a system command
is transferred to the BML, the command triggers the
desired action if permitted in the current application state.
Command
Name
0x01 (1)
ParamUploadStart
0x02 (2)
ParamUploadEnd
0x03 (3)
ParamDownloadStart
0x04 (4)
ParamDownloadEnd
0x05 (5)
ParamDownloadStore
0x40 (64)
Teach Apply
0x41 (65)
SP1 Single Value Teach
0x42 (66)
SP2 Single Value Teach
0x43 (67)
SP1 Two Value Teach TP1 Saves the currently measured position as Teachpoint 1 for Setpoint 1.
0x44 (68)
SP1 Two Value Teach TP2 Saves the currently measured position as Teachpoint 2 for Setpoint 1.
0x45 (69)
SP2 Two Value Teach TP1 Saves the currently measured position as Teachpoint 1 for Setpoint 2.
0x46 (70)
SP2 Two Value Teach TP2 Saves the currently measured position as Teachpoint 2 for Setpoint 2.
0x47 (71)
SP1 Dynamic Teach Start
0x48 (72)
SP1 Dynamic Teach Stop
0x49 (73)
SP2 Dynamic Teach Start
0x4A (74)
SP2 Dynamic Teach Stop
0x4E (78)
Teach Reset
0x4F (79)
Teach Cancel
0x80 (128)
Device Reset
0x82 (130)
Restore Factory Settings
0xA5 (165)
Reset Maintenance
0xAF (175)
Ping
0xE0 (224)
Teach Preset
0xE1 (225)
Teach Measurement
Range Lower Limit
0xE2 (226)
Teach Measurement
Range Upper Limit
see Section 7.5.3 Setpoint teach-in on page 32
1)
Tab. 7-5:
System commands Index 2, Subindex 0
www.balluff.com
Description
Starts parameter upload.
Ends parameter upload.
Starts parameter download.
Ends parameter download.
Finishes parameter setting and starts data storage.
Verifies the Teach points and applies them to the configuration.
Saves the currently measured position as a Setpoint 1.
Saves the currently measured position as Setpoint 2.
Begins dynamic teaching for Setpoint 1.
Ends dynamic teaching for Setpoint 1.
Begins dynamic teaching for Setpoint 2.
Ends dynamic teaching for Setpoint 2.
Deletes settings, SP1 and SP2 value of the currently selected SSC.
Cancels the current Teach procedure.
Reinitializes all device components.
Resets all configurations to their factory settings.
Resets all maintenance parameters.
LED changes to Device Discovery Blink pattern (2 × short blinking, with 1
second repetition for a duration of 1 minute).
Calculates and saves the PDV offset, sets the current output value to the
preset value.
Teaches the current position as the lower limit of the measuring range (see
Section 7.5.1).
Teaches the current position as the upper limit of the measuring range (see
Section 7.5.1).
1)
1)
1)
1)
1)
1)
1)