Technical Data Finish 250; Technical Data Finish 270 - WAGNER Finish 270 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
descrIptIon of unIt
Before start with the backfitting, pull of main
plug of socket, disassemble suction system
and high pressure hose
3.6

tecHnIcAl dAtA FInISH 250

Voltage :
Fuses :
Unit connecting line :
Max. current consumption
hose heating :
Degree of protection :
Acceptance capacity :
Max. operating pressure :
Max. volume flow :
Volume flow at 12 MPa
(120 bar) with water :
Max. temperature of the
coating material :
Max. viscosity :
Empty weight pump :
Hydraulic oil filling
quantity :
Max. vibration at the spraygun
:
Max. sound pressure level:
*Place of measurement: 1 m distance from unit and 1.60
m above floor, 12 Mpa (120 bar) operating pressure,
reverberant floor
38
1
230 V AC, 50 Hz
16 A time-lag
4 m long, 3 x 1.5 mm²
4,6 A
IP 54
1,1 kW
25 MPa (250 bar)
2.2 l/min
1.8 l/min
43 °C
15,000 mPas
28 kg
0.65 liter
lower than 2.5 m/s²
74 dB (A)*
3.7

tecHnIcAl dAtA FInISH 270

Voltage :
Fuses :
Unit connecting line :
Max. current consumption
hose heating :
Degree of protection :
Acceptance capacity :
Max. operating pressure :
Max. volume flow :
Volume flow at 12 MPa
(120 bar) with water :
Max. temperature of the
coating material :
Max. viscosity :
Empty weight pump :
Hydraulic oil filling
quantity :
Max. vibration at the spraygun
:
Max. sound pressure level:
*Place of measurement: 1 m distance from unit and 1.60
m above floor, 12 Mpa (120 bar) operating pressure,
reverberant floor
Finish 270 / 250
230 V AC, 50 Hz
16 A time-lag
4 m long, 3 x 1.5 mm²
6.0 A
IP 54
1.3 kW
25 MPa (250 bar)
2.9 l/min
2.3 l/min
43 °C
15,000 mPas
29.5 kg
0.65 liter
lower than 2.5 m/s²
74 dB (A)*

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Finish 250

Table des Matières