10 | EV 3000 | Installation
CAUTION – Loop-back Self-Test
Adapter - Overload
Possible risk of personal injury
Do not apply power to EV 3000
through the self-test adapter
barrel connector unless the
circuit is protected by a fuse,
circuit breaker, or current-lim-
ited power supply. The fuse,
circuit breaker, or current-limit-
ed power supply must be set to
no more than 3 amps.
i
50A NFB with 30mA RCD-type A is recom-
mended
8.5.1
Remove Front Cover
Remove two M5 screws from the front
1.
cover of the EV 3000 charging unit (see
Fig. 9).
Press the cover release button on the top
2.
left corner of the EV 3000 charging unit
(see Fig.
9).
Fig. 9:
Removing front cover
1. M5 screws
2. Cover release button
|
SP0 150 2139
VER.00
8.5.2
Prepare Cables for Connection
i
Use XLPE power cables or equivalent for AC
input connection.
i
If XLPE cable is not available, use suitable
liquid tight cable and hardware. The require-
ment of conduit must be according to local
laws and regulations.
i
Power cable outer diameter is between
32mm and 40mm.
Crimp 6.4mm inner diameter and 16.5mm
1.
outer diameter terminals to L1, L2, L3 and
N must cables.
2.
PE must chose terminals with inner diame-
ter 5.3mm and outer diameter 12mm.
Feed cables through cable gland and into
3.
the
EV 3000 AC
inlet.
!
The requirements of conduit must be
according to EN61386-24 or local laws,
codes, or regulations.
8.5.3
Connect Power Terminals
Using M6 screws, fasten L1, L2, L3, and
1.
N wires onto the 4P terminal, and torque
each screw to 30Kgf.cm/5-15 secs (see
Fig. 10).
PE
Fig. 10:
Power terminal connections
2.
Using M5 screw, fasten PE wire to bus-bar,
and torque to: 27Kgf.cm/5-15 secs.
Fasten cable grand.
3.
© Bosch Automotive Service Solutions Inc.
N
L3
L2
L1
AWG #4 x4