Installation, Pneumatic - Festo DDLI-25 Notice D'utilisation

Masquer les pouces Voir aussi pour DDLI-25:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 51
DDLI-25/32/40/63
5.2

Installation, pneumatic

When using in a vertical or sloping position:
Warning
Uncontrolled moving masses can cause personal injury and material damage (risk of
crushing). If there is a pressure failure, the moveable load (slide mass + mass of the
effective load) will slide down.
• Read the documentation for your controller (e.g. CPX-CMAX). There you will find
information on pneumatic circuits with which the moveable mass can be prevented
from falling down.
• Check whether safety measures are required to prevent slow sinking as a result of
leakage (e.g. toothed latches or moveable bolts).
• Connect the tubing connections in the supply ports. The
threaded connectors are marked with different colours on the
releasing ring:
– blue releasing ring at connection 2:
movement to the right towards the measuring system end
– black releasing ring at connection 8:
movement to the left towards the measuring system
connection
The required tubing O.D. is summarised in the following table
(
Tab. 4).
Size
Stroke [mm]
25
100 ... 160
225 ... 2000
32
100
160 ... 2000
40
100 ... 750
850 ... 2000
63
100 ... 300
360 ... 450
500 ... 2000
Tab. 4
26
2
Fig. 7
Tubing outside diameter [mm]
6
8
6
8
8
10
8
10
12
Festo – DDLI-25/32/40/63 – 1402a English
8

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ddli-32Ddli-40Ddli-63

Table des Matières