SIGFOX SENSORS - Mode d'emploi / User guide version V2.1.1

2.4. Configuring the SIGFOX SENSORS unit (analog input)

In this configuration, the device send a periodic data frame following the choosr setting. This mode is only available when the analog type
sensor are selected for both ways.
The SIGFOX SENSORS is configured via the combination of switches. The following settings can be changed:
Transmission interval
Inputs activation (sensors 1 and 2)
The type of sensor connected

CONFIGURATION TABLE:

Parameter
Value
2 frames per day
Transmission frequency
50 frames per day
(Only Available on
100 frames per day
Analog Input Mode)
140 frames per day
Sensors 1&2 inactives
Sensor 1 active
Activation of sensor
inputs
Sensor 2 active
Sensor 1&2 actives
Sensor type
Sensor 1&2 ANA
PLEASE NOTE: You must set your switches before activating the meters. Once at least one way is activated and the SigFox SENSORS has been
started via magnet, the configuration with the switchs can no longer be possible.
If the configuration has any difference between the switchs and the product register value, the consistency error bit will be set to on in the
frame. This consistency verification is carried out every minute.
All manuals and user guides at all-guides.com
SW1
SW2
SW3
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
ON
OFF
ON
SW4
SW5
SW6
OFF
OFF
ON
ON
OFF
OFF
Page
35
of 45
GB