Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SIGFOX SENSORS - Mode d'emploi / User guide version V2.1.1

4.1.4 Status

Low bat error = 1 if supply voltage <= 2.5 V, else 0
Configuration switch error = 1 if no switch consistency, else 0
HW error = 1 if hardware failure, else 0
Configuration done = 1 if last downlink frame was a right frame and configuration done, else 0 (this byte is set to 1 during the next 3
frames following a correct downlink frame)
Alarm/Status
No error
Low bat error
Configuration Switch error
HW error
Configuration done

4.2. Parametres

Name
Default value Possible values
Device Type
0
Transmit period
0
Debounce Time
0
Channel On/Off
0
1 channel = 1 sensor /
pulse counter
Channel 1 Type
0
Channel 2 Type
0
Switch value
0
IMPORTANTE NOTE 1 : A value under 600 secondes cannot be used for the transmit period to respect the radio compliance. For the digital
product make sure the application is compliance too.
All manuals and user guides at all-guides.com
Bit7
Bit6
Bit5
Frame counter
0x0 à 0xF
0 : None
1 : Sensors
0 = Switch
1 to 43200 seconds
0 = Switch
1 to 65 seconds
0 : all channel Off
1 : channel 1 On
2 : channel 2 On
3 : : channel 1 and 2 On
0 (0x00) = Sensor (selection by switch)
1 (0x01) = Sensor analog, auto mode (0/10V or 4/20mA)
2 (0x02) = Sensor Dry Contact
11 (0x0B) = Sensor 4-20 mA
12 (0x0C) = Sensor 0-10V
0 (0x00) = Sensor (selection by switch)
1 (0x01) = Sensor analog, auto mode (0/10V or 4/20mA)
2 (0x02) = Sensor Dry Contact
11 (0x0B) = Sensor 4-20 mA
12 (0x0C) = Sensor 0-10V
0x00 to 0x3F
0x00 to 0x3F = DIP switchs position
0 switch set to OFF
1 switch set to ON
Order switchs : SW1-SW2-SW3-SW4-SW5-SW6
Bit4
Bit3
Bit2
HW
Switch
0
0
0
0
0
1
1
0
0
0
Bit1
Bit0
Low bat
Configuration
0
0
1
0
0
0
0
0
0
1
Data size
8 bits
16 bits
16 bits
8 bits
8 bits
8 bits
8 bits
Page
44
of 45
GB