2.4. Configuring the SIGFOX SENSORS

Your SIGFOX SENSORS is configured via the combination of switches. The following settings can be changed:
Transmission interval
Inputs activation (sensors 1 and 2)
The type of sensor connected (analogue or digital -On-Off-)
Note : Activation of the sensors and the type of sensors (analogue or digital -On-Off-) can only be done via the switches
CONFIGURATION TABLE:
Parameter
Value
2 frames per day
50 frames per day
Transmission frequency
100 frames per day
140 frames per day
Sensors 1&2 inactives
Sensor 1 active
Activation of sensor
inputs
Sensor 2 active
Sensor 1&2 actives
Sensor 1&2 ANA
Sensor 1&2 Dry Contact
Sensor type
Sensor 1 ANA, Sensor 2 Dry Contact
Sensor 1 Dry Contact, Sensor 2 ANA
PLEASE NOTE: you must set your switches before activating the meters. Once the SIGFOX SENSORS has been started via a magnet, the confi-
guration can no longer be changed.
If you change the switch configuration after activation, the product will transmit a switch consistency error frame. This consistency verification is
carried out every minute.

2.5. Closure of the case

Once steps 3.2, 3.3 and 3.4 have been completed, you can close the SIGFOX SENSORS's case.
Procedure:
Make sure the seal is installed correctly on the case plate.
SW1
SW2
SW3
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
ON
OFF
ON
Seal
SW4
SW5
SW6
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
ON
ON
OFF
Page
34