Wiring Diagram - Toshiba Carrier RAV-SP180KRT-UL Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

+001111052201_00Ta.book Page 19 Friday, November 20, 2009 11:45 AM
High-Wall Type
9. Attach the conduit cover.
Indoor/Outdoor
connecting wire
11.0"
(280 mm)
10.Attach the terminal cover, the front panel
and the air inlet grille to the indoor unit.
CAUTION
• Be sure to refer to the wiring diagram attached
inside the front panel.
• Check local electrical cords and also any
specific wiring instructions and limitations.
• Beware of the metal plate edge when working
on the unit. The edge can be sharp and may cut
your hand.
• Firmly tighten the screws of the terminal block.
Keep the wire length as shown in figure below when
it is connected to the terminal block.
Indoor/Outdoor unit
connecting wire

Wiring Diagram

208/230-1-60
Indoor
unit
L
1
High voltage
L
1
Outdoor
unit
19-EN
All manuals and user guides at all-guides.com
Conduit cover
L
S
2
L
S
2
– 19 –
▼ When using optional wired remote controller
1. Remove the air inlet grille.
Open the air inlet grille upward and pull it
toward you.
2. Remove the front panel.
3. Remove the terminal cover and the clamp
base.
Terminal block for
Indoor/Outdoor connecting
Clamp base
Screw
Screw
Terminal Cover
4. Insert the wired remote controller wire fully
into the wired remote controller/central
control terminal block,
A
secure it tightly with screws.
• Strip off the wire approx. 0.4" (9 mm) to
connect.
• Non polarity, 2 core wire is used for wiring
of the wired remote controller.
(2 x AWG20)
L
L
S
1
2
U
U
A
B
3
4
Hole for remote
Cord clamp
controller wires
Installation Manual
L
L
1
2
S
Terminal block
and
and
B
,
Terminal
block for
wired
remote
controller/
central
control
wiring
Wired remote
controller wire
Hole for indoor/
outdoor connecting
wires and ground
wire
Toshiba

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Carrier rav-sp240krt-ul

Table des Matières