Accessories; Brine Circuit Manifold; Transport; Installation - Dimplex SI 5MSR Instructions D'installation Et D'utilisation

Table des Matières

Publicité

4

Accessories

4.1 Brine circuit manifold

The brine circuit manifold merges the individual collector loops of
the heat source system into a single main pipe which is con-
nected to the heat pump. Integrated ball valves allow the individ-
ual brine circuits to be shut off for de-aeration purposes.
5

Transport

A lift truck is suited for transporting the unit on a level surface.
Carrying straps may be used if the heat pump needs to be trans-
ported on an uneven surface or carried up or down stairs. These
straps can be passed directly underneath the wooden pallet.
ATTENTION!
The heat pump is not secured to the wooden pallet.
ATTENTION!
The heat pump must not be tilted more than 45° (in any direction).
Use the holes provided in the sides of the frame to lift the unit
without the pallet. The side panel assemblies must be removed
for this purpose. Any commercially available length of pipe can
be used as a carrying aid.
ATTENTION!
Do not use the holes in the panel assemblies for lifting the device!
E-4
All manuals and user guides at all-guides.com
6

6.1 General Information

The unit must be installed indoors on a level, smooth and hori-
zontal surface. The entire base of the frame should lie directly on
the floor to ensure a good soundproof seal. If this is not the case,
additional sound insulation measures may be necessary.
The heat pump must be installed so that maintenance work can
be carried out without being hindered. This can be ensured by
maintaining a clearance of approx. 1 m in front of and on each
side of the heat pump.

6.2 Acoustic Emissions

The heat pump operates silently due to efficient sound insulation.
To prevent vibrations from being transmitted to the foundation, a
suitable, sound dampening rubber mat should be placed under-
neath the base frame of the heat pump.
To prevent any sound from being transmitted to the heating sys-
tem, we recommend connecting the heat pump to the heating
system by means of hose sections.

Installation

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Si 7msrSi 9msrSi 11msr

Table des Matières