CoDe
PossIble CAuse
1
Unloader valve does not release pressure when air tank
reaches blow-off pressure

Fittings are not tight
3
Defective unloader valve
4
Defective air tank
5
Leaking seals
6
Defective safety valve
7
Prolonged excessive use of air
8
Compressor is not large enough for accessory
9
Hole in air hose
10
Unloader valve restricted
11
Unit operating in damp or humid conditions
1
Restricted air intake filter
All manuals and user guides at all-guides.com

Troubleshooting Codes

18
PossIble solutIon
Unloader valve must be replaced. Contact a D
tory service center or a D
WALT authorized service center.
e
Tighten fittings where air can be heard escaping. Check fit-
tings with soapy water solution. DO NOT OVERTIGHTEN.
Turn off engine, rotate manual lock unloader lever to the
closed perpendicular position. If air leaks out of air tank
through unloader valve, replace unloader valve.
Air tank must be replaced. Do not repair the leak.
WARNING: Risk of bursting. Do not drill into, weld or oth-
erwise modify air tank or it will weaken. The air tank can
rupture or explode.
Contact a D
WALT factory service center or a D
e
authorized service center.
Operate safety valve manually by pulling on ring. If valve
still leaks, it must be replaced.
Decrease amount of air usage.
Check the accessory air requirement. If it is higher than the
CFM or pressure supplied by your air compressor, a larger
compressor is needed to operate accessory.
Check and replace air hose, if required.
Remove, clean or replace.
Move unit to a dry well ventilated area
Clean or replace air intake filter
WALT fac-
e
WALT