16.2 Display of safety devices and commands
i
NB: the safety device and command display mode is only visible with Display visualisation
mode set at 01 or 03.
Display
1-2 - Automatic closing activation com-
mand
1-3 - Opening command
1-4 - Closing command
1-5 - Step-by-step command
P3 - Partial opening command.
4P - Closing command with operator
present
RX - Radio reception (of any memo-
rised key of a transmitter present in the
memory)
NX - Radio reception (of any non-mem-
orised key)
NB: with the selection
, it is also visualised when a com-
mand is received from a non-stored
transmitter.
EX - Rolling-code radio reception out of
sequence
EP - Radio reception not complying with
the parameter configuration
CX - Command received from AUX1 board
FC. - Closure limit switch
FA. - Opening limit switch
SW - Release door open.
When the release door is closed, the con-
trol panel performs a RESET (alarm
EN
Description
Display
68 - Partial opening command
1-6 - Safety device with opening and
closing stop
S1. - Detection of stop during closure
1-8 - Safety with closing reversal
1-9 - STOP command
3P - Opening command with operator
present
S2. - Detection of stop during opening
OO.- Obstacle detection area reached
during opening
OC. Obstacle detection area reached
during closure
RV - Enabling/disabling of built-in radio
receiver via RDX
MQ - Learning operation of mechanical
end stops in progress
HT - Heating of the motors (NIO function)
in progress
HS - Sharp NIO start-up
JR1 - Variation of the JR1 jumper status
)
42