12. Commands
i
You are advised to read paragraph 15 for all the details about the possible adjustments.
WARNING: terminal 30 (common positive for commands) has the same functions as terminal 1, so
the commands visualised on the display are indicated with 1-5, 1-3, etc.
It is different from terminal 1, however, because of the maximum current that can be dispensed
and it is also active when the control panel is in standby
Command
30
5 NO
1
6
1
6
1
8
1
6
8
1
20
20 NC
1
WARNING: make a jumper for all NC contacts if not used, or deactivate them via the relative menu.
Terminals with the same number are equal.
EN
Function
When selecting
tivates a sequential opening or closing operation: opening-stop-
closing-opening.
STEP-BY-STEP
WARNING: if automatic closure is enabled, the duration of the
stop can be defined by selecting
The "opening-stop-closing-opening" sequence can be changed
to "opening-stop-closing-stop-opening" by selecting
When selecting
OPENING
tivates an opening operation.
When selecting
NO
CLOSURE
a closing operation.
When selecting
stops and prevents any movement.
NC
SAFETY STOP
NB: to set different safety contact functions, see the
parameter settings.
The opening of the safety contact triggers a reversal of the
movement (reopening) during the closing operation.
CLOSING
When selecting
NC
SAFETY
vents any operation when the automation is idle.
DEVICE
When selecting
prevents closure when the automation is idle.
The opening of the safety contact stops and prevents any move-
CLOSING/
ment.
OPENING
NC
NB: operation corresponds to that of contact 1-6 with
SAFETY
DEVICE
The closure of the contact activates a partial opening operation.
PARTIAL
Once the automation stops, the partial opening control performs
NO
OPENING
the opposite operation to the one performed before the stop.
Selecting
enables automatic closure if
AUTOMATIC
Selecting
CLOSURE OR
STOP
causes the movement to stop.
NB: the flashing light flashes.
Description
.
, the permanent closure of the contact
20
.
, the closure of the contact ac-
.
, the closure of the contact ac-
, closing the contact activates
, opening of the safety contact
, the opening of the contact pre-
, the opening of the contact only
.
, the opening of the safety contact
.