VC - Selection of closing speed
• LO: 15 cm/s
• ME: 20 cm/s
• HI: 25 cm/s
D6 - Selection of device connected to terminals 1-6
• NO: none
• PH: photocells
For other options, see the specific menu.
D8 - Selection of device connected to terminals 1-8
• NO: none
• PH: photocells
For other options, see the specific menu.
RM - Radio receiver operation
• 1-3: Step-by-step
• 1-5: opening
EP - Setting the coded area messages
If the possibility to receive coded messages is enabled, the control panel will be compatible
with remote controls of the "ENCRYPTED" type.
• ON: enabled
• OF: disabled
SR - Remote control storage
When you press ENTER, SR starts to flash and you can associate the desired buttons. Once
OK is displayed, SR starts to flash again and you can associate the next button.
To quit, press ESC or ENTER for 2 seconds and go on to the next item.
NB: if NO flashes on the display, the remote control may already be stored.
CO - Saving of parameters
Here you can save the parameters that have previously been set.
• YS: to save and perform a card RESET
• NO: to quit without saving and go back to a blank screen (central part only)
NB: the CO item and YS/NO sub-menus flash constantly.
To save the configuration:
In the CO parameter select YS (yes) and press the ENTER button for 2 seconds.
When the configuration has been saved, a power reset is automatically performed on the card.
To quit without saving changes:
In the CO parameter select NO and press the ENTER button for 2 seconds.
Or: from any main parameter, press the ESC button for 2 seconds.
Example
for 2 sec
.
NOTES
• The set values are only stored on the card if they are saved using the CO parameter.
• The CO parameter and YS/NO options flash constantly.
• When a configuration item is confirmed, it automatically moves on to the next parameter.
• You can scroll through the menu parameters using the UP/DOWN buttons.
• There is no automatic timeout function to quit.
(default)
(default)
(default)
(default)
(default)
for 2 sec
.
for 2 sec
.
19