15.4 Second level menu - BA (Basic Adjustment)
Display
TC - Setting of automatic closing time [s]
It is set with different intervals of sensitivity.
• from 0" to 59" with intervals of 1 second
• from 1' to 2' with intervals of 10 seconds
RP - Adjustment of partial opening measurement [%]
Adjusts the percentage of operation in relation to the total opening
of the automation.
10 - Minimum
99 - Maximum
TP - Setting of automatic closing time after partial opening [s]
It is set with different intervals of sensitivity.
• from 0" to 59" with intervals of 1 second
• from 1' to 2' with intervals of 10 seconds
VA - Opening speed [cm/s]
VC - Closing speed [cm/s]
R1 - Adjustment of thrust on obstacles and motor current during
opening. [%]
The control panel is fitted with a safety device which, when it de-
tects an obstacle:
- stops the movement and, if outside the obstacle detection
area, performs a reverse movement regulated by the selection
;
The obstacle detection area during opening is determined by the
type of limit switch installed. If there is no limit switch, it is deter-
mined according to the selection
00 - Minimum thrust
99 - Maximum thrust
Description
.
27
Selections
available
1'00"
30
30
20
20
50
EN