Problem
The remote control
The radio transmission is im-
has limited range
peded by metal structures and
and does not work
reinforced concrete walls.
with
the
auto-
mation
moving.
The remote control
No storage module or incor-
does not work
rect storage module.
The flashing light
The wires of the flashing light
is not working
are detached or have short
circuited.
Possible cause
47
Alarm
signalling
Install the antenna outside.
Replace the transmitter batteries.
Switch the automation off and plug in the
correct storage module.
Check the correct memorisation of the
transmitters on the built-in radio. If there
is a fault with the radio receiver that is
built into the control panel, the remote
control codes can be read by removing
the storage module.
Check the connections.
If the problem persists, contact Techni-
cal Service.
Operation