Theoretical Recoil Force Diagram For Airless Spray Tips; Spray Tip Selection - WAGNER EP 3000 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Theoretical recoil force diagram for Airless spray tips

135
130
125
120
115
110
105
100
95
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
0
*Measured with water
This is the force acting on the gun and transmitted to the hand guiding the gun. Values for higher spraying
pressures can be calculated proportionally.
Attention: An additional turning moment may be caused when using pole guns. Hold pole gun with both hands.

Spray tip selection

Selection of the correct tip is essential for correct and efficient spraying. In many cases, the right tip can be
determined only by conducting a spray test.
Here are a few rules:
The spray fan must be uniform.
If streaks appear in the spray fan, the spraying pressure is too low or the viscosity of the material is too high.
Remedy: Increase pressure or thin the material. Each pump delivers a specific volume directly proportional to the
size of the tip:
Rule of thumb: large tip = low pressure
small tip = high pressure
A very wide range of tips is available with widely ranging spaying angles.
GB
Pressure, bar
35
Spray tip bore
mm
1.98
1.83
1.57
1.30
1.10
0.91
0.79
0.66
0.53
0.46