Main Elements Of The Wagner Ep 3000; Drive; Electric Motor; Motor Safety Switch - WAGNER EP 3000 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Main elements of the WAGNER EP 3000

1. Drive

3
2
1
1 Switch box
2 Pressure regulator switch

3 Mains cable

4 Electric motor

Important: When using on building sites use 16 A slow-
blow fuses because of possible drops in voltage.
Electric motor
The electric motor is maintenance-free.
EP 3000 230 V ~, 50 Hz
The unit has a single-phase induction motor with
operational capacitor.

Motor safety switch

The safety switch automatically switches the motor off if
it overloaded.
After about 2 - 3 minutes switch the motor safety switch
back on.
Mains cable
EP 3000 230 V~, 50 Hz
Length 6 m, diameter 3 x 2.5 mm
and specification HO7 RN-F3G2.5.
EP 3000 400 V~, 50 Hz, V3~
Length 6 m, diameter 5 x 1.5 mm
and specification HO7 RN-F5G1.5.
GB
4
E P
3 0
0 0
2
2
27
Attention: It is absolutely necessary that you use an
extension cable with the above named specifications.
Cable length up to 100 m depending on the coating
material used. The extension cable must be rolled out
completely. Furthermore, make sure that the
connections are in perfect working order! Loss of
voltage makes it more difficult to start the motor and
reduces the performance of the unit.

2. Gear unit

5
5 Electro-magnetic coupling
6 Cycloidal gear
7 Eccentric
The gear unit includes the electro-magnetic coupling (5),
the cycloidal gear (6) and the eccentric (7). The coupling
is self-adjusting and the whole unit is maintenance-free.
2
3 x 2.5 mm
5 x 1.5 mm
2
6
7