Clearance To Combustibles; Propane Gas Connection - Jackson Grills LUX700BI Manuel D'utilisation

Pour modèles encastrables - jls700bi-lp propane liquide / jls700bi-ng gaz naturel
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

A) TOP: Minimum clearance from grill surface to combustible construction*:
*Such as decks, ceilings, hanging plants, etc.
B) REAR: from rear of unit to any combustibles behind grill:
C) SIDE: from the outside edges the grill body, to any adjacent combustibles: 15.5 inches minimum
Please allow extra space when the grill is backed up to vinyl siding;
exhaust exiting the rear of the grill can warp or melt the vinyl.
FUEL TYPE: The following instructions are for a Propane configured grill. Operating Pressure: 11" WC.
HOSE & REGULATOR: The pressure supplied to the grill must conform to what is listed on the rating plate
of the grills (11" WC). If the supply pressure is great, a regulator must be installed (regulator not included).
BUILT IN PROPANE GAS HOOK-UP:
The piping up to the gas grill is the responsibility of the qualified installer and piping should be located as
1.
shown below. (Fig. 7)
2. A flexible metal connector pipe is included to simplify the installation of the unit.
3. Connect this flexible metal connector to the flare fitting on the end of the manifold.
4. Connect the other end of the connector to the gas piping.
5. The Flexible connector must not pass through a wall, floor, ceiling or partition, & is protected from damage.
6. Do not use a hose to connect the unit except to connect the cylinder regulator to the piping system.
7. Do not run hose in areas where heat damage could melt or burn the hose.
8. The propane hose & regulator assembly must be
connected with rigid pipe, copper tube, or an
approved flexible metal connector which
complies with Z21.4/CSA 6.10.
9. The installation must comply with CAN B149.1
Natural Gas and Propane installation code in
Canada, or to the National Fuel Gas code,
ANSI Z223.1 in the United States.
10. The gas supply pipe must be sufficiently sized
to supply the BTU/h specified on the rating
plate, based on the length of the piping run.
11. If installing a side burner, a spate line must be
branched off to the side burner unit and
enter the side burner opening at the
specified location.

Clearance to Combustibles:

!WARNING!

Propane Gas Connection:

Typical 20lb. Propane Cylinder Connection
9
Do not use this appliance
under overhead
combustible surfaces
12 inches minimum
Figure 7

Publicité

Chapitres

Table des Matières
loading

Table des Matières