The Solea must not be built into the wall, and must be placed on a oor that is solid enough to hold the
appliance. The distance from the Solea to the rear wall must be at least 10 cm, and there must be a free space
of at least 20 centimetres to the right and left side of the replace. Be sure to place the Solea on a solid oor
plumb under the ue pipe.

Insulation

Due to the high temperatures of the exterior walls (up to approximately 150 °C or 300 °F) it is prohibited to
have or to place any combustible materials close to the channel system. The entire concentric pipe system
should be encased with reproof material from the place where it is out of sight up to the outlet in the exterior
wall. Ventilate the encased concentric pipe system by placing a grate near the oor and the ceiling on every
oor. Use universal wall clips with a diameter of 150 mm for anchoring the concentric pipe system.
If an existing chimney is used, rst make sure whether the chimney is su ciently insulated and is wide
!
enough to accommodate the concentric pipe system. If the chimney was previously used as a wood-
burning or coal- red stove, it must rst be professionally cleaned. You must use special WANDERS
connecting sets for connecting a gas hearth to an existing chimney.

Gas connection

Use a feed pipe with an approved G3/8" stop cock with coupling.
De-aerate the supply pipe before tting and fastening the appliance.
Avoid tension on the operating valve and pipes to avoid gas leakage.
Check if the connection is gastight.

Placing the concentric channel system

The appliance is approved according to the European CE regulations for gas appliances with the WANDERS
concentric ue systems (Ø 80 / 150 mm) and are to used only in that combination. The warranty will be partly
or entirely invalid if another system is used during installation. The WANDERS concentric system (Ø 80 / 150
mm) can be used with existing situations or newly built situations.

Instructions for placing the out ow

The out ow of the pipe system can be placed on top of the roof or against the side
wall of the house.
Out ow on top of the roof
When placing the out ow on top of the roof, make sure that there is a distance of at
least 50 cm between the out ow and the edges of the roof, with the exception of a
possible existing ridge. You must also take the place of the out ow into account in
relation to the existing ventilation openings, movable windows and combustion air
supply provisions. Please consult the national and local requirements.
Out ow into the wall
When placing the out ow into the side wall, make sure that there is distance of at least
50 cm between the out ow and the corners of the building, eaves, gutters, balconies
and etceteras. You need not have this distance when the out ow runs to at least the
front side of the overhanging part.
You must also take into consideration the place of the out ow in relation
!
to the existing ventilation openings, movable windows and combustion air
supply provisions. Please consult the national and local requirements.