Supervisor Key (Yellow) - Nilfisk SC2000 Instructions D'utilisation

Masquer les pouces Voir aussi pour SC2000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH

SUPERVISOR KEY (yellow)

The supervisor key (yellow) allows to check some additional information on some machine operating parameters and to adjust
some settings according to specific requirements.
Main Screen (E, Fig. 7)
1.
Put the supervisor key (yellow) in the key reader (41)
instead of the user key (blue), then press the push-button
(42) to open the main screen on the display.
2.
Press push-button (A) to change the machine settings (see
Machine Settings Screen section).
3.
Press push-button (B) to check for any stored machine
alarms (see Alarms Log Screen section).
4.
Press push-button (C) to check the machine's hours of
operation (see Operating Time Counter Screen section).
5.
Press the push-button (D) to enter the user key
management menu (see the User Key Management
Screen paragraph).
Machine Settings Screen (F, Fig. 7)
This function allows you to customise some parameters
described in the following table of modifiable parameters.
1.
Press push-button (B) to increase the value of the current
parameter.
Press push-button (C) to decrease the value of the current
parameter.
2.
Press push-button (A) to move to the next parameter.
3.
To return to the main screen, press and hold the push-
button (A) for more than 1 second.
TABLE OF MODIFIABLE PARAMETERS
Code
Description
CHM1
Detergent concentration level 1
CHM2
Detergent concentration level 2
P1/P3
Level 1 solution flow rate in relation to level 3
(flow rate as function of speed)
P2/P3
Level 2 solution flow rate in relation to level 3
(flow rate as function of speed)
P3
Level 3 solution flow rate (flow rate as function of speed)
P4
Level 4 enabling (2.8 l/min regardless of speed)
SPT
EcoFlex function timer
XPRES
Brush deck extra pressure enabling
FVMAX
Maximum forward speed
RVMAX
Maximum reverse speed
WSMIN
Minimum working speed
WSMAX
Maximum working speed
BRK
Electromagnetic brake activation delay
BAT (**)
Installed battery type (see table)
TOFF
Automatic shut-off time
BRGH
Display contrast
VRID
Silent mode setting
RPM (*)
Reduced brush rpm activation threshold
RESET
Restore factory settings for all parameters
(*)
Increase the value of this parameter to reduce the brush motor speed in a wider range of applications and vice versa.
20
INSTRUCTIONS FOR USE
SC2000 - 9100000383
E
F
Figure 7
Values
Minimum
Factory Setting
0.25 % (1:400)
0.25 % (1:400)
0.25 % (1:400)
0.80 % (1:125)
0 %
25 %
50 %
0 %
1.0 cl/m
3.0 cl/m
OFF
OFF
0 (disabled)
60 sec.
OFF
ON
100 %
10 %
40 %
10 %
10 %
25 %
10 %
100 %
0 sec.
1 sec.
0
1
300 sec.
0 (disabled)
5
15
1
1
5
9
OFF
OFF
revised 07/2017
A
B
C
D
P100869
Maximum
3 % (1:33)
3 % (1:33)
100 %
100 %
5.0 cl/m
ON
300 sec.
ON
100 %
50 %
100 %
100 %
5 sec.
5
600 sec.
50
5
20
ON
01/2015

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

9087410020908741102090873600209087364020

Table des Matières