Thank you for buying this product, our company is sure that you will be more
than satisfied with the product's performance. The product is supplied with a "War-
nings" leaflet and an "Instruction booklet". These should both be read carefully
as they provide important information about safety, installation, operation and
maintenance. This product complies with the recognised technical standards and
safety regulations. We declare that this product is in conformity with the following
directives: CAN/CSA-C22.2 No. 247-92 UL Std. No. 325 (Certificate: 1002906 Date
Issued: October 16, 2000).
1) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product can cause
damage to persons, animals or property.
The "Warnings" leaflet and the "Instruction booklet" supplied with this pro-
duct should be read carefully as they provide important information about
safety, installation, operation and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according to the
provisions set out by current standards. Keep nylon or polystyrene bags out
of children's reach.
Keep the instructions with the technical brochure for future reference.
This product was exclusively designed and manufactured for the use specified
in the present documentation. Uses not specified in this documentation could
cause damage to the product and be dangerous.
The Company declines all responsibility for any consequences resulting from
the product being used improperly or differently from whatever is specified
in the present documentation.
Do not install the product in an explosive environment.
The Company declines all responsibility for any consequences resulting from
failure to observe Good Technical Practice when constructing closing structures
(door, gates etc.), as well as from any deformation which might occur during
use.
Disconnect the electrical power supply before carrying out any operations
on the plant. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar circuit breaker or thermal magnetic circuit breaker on the
mains power supply, having a contact opening distance equal to or greater
than 0.11 in (3 mm).
Check that a differential switch with a 0.03A threshold is fitted just before the
power supply mains.
Check that earthing is carried out correctly: connect all metal parts for closure
(doors, gates etc.) and all system components provided, with an earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are needed
to protect the area from any danger caused by squashing, conveying and
shearing.
Position at least one light signal device (blinker) where it can be easily seen,
and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the automation safety and
good operation when other manufacturers' components are used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised by
the Company.
Instruct the product user about the control systems provided and the manual
opening operation in case of emergency.
Do not allow persons or children to remain in the automation operation area.
Keep radio control or other control devices out of children's reach, in order to
avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the automation
system, but only request assistance from qualified personnel.
Anything which is not expressly provided for in the present instructions, is
not allowed.
INSTALL THE GATE OPERATOR ONLY WHEN:
The operator is appropriate for the construction of the gate and the usage
Class of the gate,
All exposed pinch points are eliminated or guarded,
The operator is intended for installation only on gates used for vehicles.
Pedestrians must supplied with a separate access opening,
The gate must be installed in a location so that enough clearance is supplied
between the gate and adjacent structures when opening and closing to reduce
the risk of entrapment. Swinging gates shall not open into public access areas,
The gate must be properly installed and work freely in both directions prior to
the installation of the gate operator. Do not over-tighten the operator clutch
or presure relief valve to compensate for a damaged gate.
FOR GATE OPENERS WITH HOLD-TO-RUN CONTROL:
The gate operator controls must be placed so that the user has full view of
the gate area when the gate is moving,
A sign with the message "WARNING" must be positioned near the controls.
The characters for the writing should be at least 6.4 mm high. The following
statement should also be indicated: "Moving Gate Has the Potential of Inflicting
Injury or Death - Do Not Start Gate Unless Path is Clear".
An automatic closing device (such as a timer, loop sensor, or similare device)
shall not be employed
No other activation device shall be connected.
8 -
P7 - P4.5
www.metalines.com
INSTALLATION MANUAL
Controls must be far enough from the gate so that the user is prevented from
coming in contact with the gate while operating the controls. controls intended
to be used to reset an operator after 2 sequential activations of the entrapment
protection device or devices must be located in the line-of-sight of the gate.
Outdoor or easly accesible controls shall have a security feature to prevent
unauthorized use.
All warnings signs and placards must be installed where visible in the area of
the gate.
FOR GATE OPENERS PROVIDED WITH SENSOR FOR CONTACT-FREE DETEC-
TION:
See instructions on the placement of non contact sensor for each type of
application,
Care shall be exercised to reduce the risk of nuisance tripping, such as when
a vheicle, trips the sensor while the gate is still moving, and
One or more non-contact sensor shall be located where the risk of entrapment
or obstruction exist, such as the perimeter reachable by a moving gate.
FOR GATE OPENERS PROVIDED WITH CONTACT DETECTION (RUBBER EDGE
OR SIMILAR):
On or more contact sensor shall be located at the pinch point of a vehicular
vertical pivot gate.
A hardwired contact sensor shall be located and its wiring arranged so that the
communication between the sensor and the gate operator is not subjected
to mechanical damage.
A wireless contact sensor such as one that transimts radio frequency (RF)
signals the gate operator for entrapment protection functions shall be loca-
ted where the transimission of the signals are not obscrtucted or impeded
y building structure, natural landscaping or similar obstruction. A wireless
contact sensor shall function under the intended end-use conditions.
IMPORTANT SAFETY INSTRUCTIONS
WARNINGS: to reduce the risk of injury or death:
Read and follow all instructions.
Never let children operate or play with gate control. Keep the remote control
away from children.
Always keep people and objects away from the gate. NO ONE SHOULD CROSS
THE PATH OF THE MOVING GATE.
Test the gate operator montly. The gate MUST reverse on contact with a rigid
object activates the non-contact sensor. After adjusting the force or the limit
of travel, reset the gate operator. Failure to adjust and retest the gate operator
properly can increase the risk of injury or death.
Use the emergency realease only when the gate is not moving.
KEEP GATES PROPERLY MAINTAINED. Read the owners manual. Have a
qualified service person make repairs to gate hardware.
The entrance is for veichles only. Pedestrians must use separate entrance.
Save these instructions.
2) GENERAL OUTLINE
A compact sturdy hydraulic piston, available in various versions according to the
user's requirements and type of operation. All models are supplied without locks
(reversible), and an electric lock is required to keep them blocked. To make the
manual manoeuvre easier, the lock can be released by means of a knob which
can be reached using the appropriate key.
The pushing force is adjusted with extreme precision by means of two by-pass
valves which provide antisquash safety. The end-of-stroke operation is electro-
nically set in the control panel by means of a timer.
All models are available with slow-down function during the closing phase.
3) MAIN AUTOMATION PARTS (Fig.1)
M)
2-pole single-phase motor, protected by thermal circuit-breaker.
N)
Hydraulic lobe pump.
O)
Distributor with adjustment valves.
P)
Cylinder with piston.
CS)
Rod cover.
S)
Tank.
SB)
Release.
T)
Head with slow-down adjustment valve.
U)
Base with articulated joint.
Components supplied: Attachments for pillars and gate - personalised release
key - drive capacitor - instruction manual.
4) TECHNICAL SPECIFICATIONS
Mod. P7 - Mod. P4.5
Power supply .................................................................................. 120Vac±10% - 50 Hz (*)
Motor ............................................................................................................................2800min
Absorbed power ............................................................................................................... 250W
Capacitor ................................................................................................................................. 8µF
Absorbed current ................................................................................................................1.1A
Max. pressure .............................(50bar) - 4MPa (40bar).......104472.2 - 83541.7 lb/ft
Pump capacity .................................... 0.6l/min - 0.9l/min.................0.16 - 0.24 gal/min
Pushing force ...............................................8000N - 6500N ................1798.5 - 1461.3 lbf
Towing force ....... .........................................6500N - 5200N.................1461.3 - 1169.0 lbf
Opening time (working stroke) .............................................................................. 45s - 30s
-1
2
sales@metalines.com