Commissioning
3.4 Programming the Transmitter
Table 3- 3
Pipe Configuration Option List Definitions
Fully Developed
1 Elbow
Dble Elbow+
Dble Elbow-
Valve
Expander
Reducer
Norm Entry
Header Inlet
Intrusions
Sensor Identification
The sensor part number located on the front face provides a detailed identification. For
example, the
Note
Check to make sure that the sensors are a matched set with the same serial numbers and
marked with an "A" and "B" (e.g., 19256A and 19256B).
28
Options
Part Number: 1011HNFS-D1HUT1-S2
Model
Hi Precision
NEMA w/F-Conn
Pipe Material
Fully developed flow, as would be expected for very long
straight pipe runs or installation downstream of a flow
condition.
Single 90 degree Elbow upstream of sensor installation.
Double out-of-plane Elbows upstream of sensor installation.
Double in-plane Elbows upstream of sensor installation.
Not available at this time.
Pipe expansion upstream of sensor installation.
Pipe reduction upstream of sensor installation.
Not available at this time.
Header or pipe manifold upstream of sensor installation.
Not available at this time.
means:
Sensor Size
Temperature
Agency Approved
FUH1010 IP65 NEMA 7 Interface Detector Quick Start
Operating Instructions, 06/2014, A5E02428148-AA