Commandes HART
B.1
Commandes universelles
L'appareil répond aux commandes universelles suivantes :
Tableau B- 1 Commandes universelles
Numéro
commande
0
1
2
3
6
11
12
13
Transmetteur FUS060 avec HART
Instructions de service, 08/2015, A5E35189921-AB
Fonction
Read Unique Identifier
Read Primary Variable
Read Loop Current And Percent Of
Range
Read Dynamic Variables And Loop
Current
Write Polling Address
Read Unique Identifier Associated
With Tag
Read Message
Read Tag, Descriptor, Date
Paramètres
254,
manufacturer_id,
device_type,
request_preambles,
universal_revision,
transmitter_revision,
software_revision,
hardware_revision <0xf8>,
physical_signaling_code <0x07>,
device_flags,
device_id
PV.DIGITAL_UNITS,
PV.DIGITAL_VALUE
PV.ANALOG_VALUE,
PV.PERCENT_RANGE
PV.ANALOG_VALUE,
PV.DIGITAL_UNITS,
PV.DIGITAL_VALUE,
SV.DIGITAL_UNITS,
SV.DIGITAL_VALUE,
TV.DIGITAL_UNITS,
TV.DIGITAL_VALUE
polling_address
254,
manufacturer_id,
device_type,
request_preambles,
universal_revision,
transmitter_revision,
software_revision,
hardware_revision <0xf8>,
physical_signaling_code <0x07>,
device_flags,
device_id
message
tag,
descriptor,
date
B
Lecture /
écriture /
commande
Lecture
Lecture
Lecture
Lecture
Ecriture
Lecture
Lecture
Lecture
97