It is mandatory to install a filter (with filtration grade at least 5 micron) on the dryer inlet
side to prevent that rust, scale or other pollutants clog the Alu-Dry Module and the
condensate drain.
Type A installation is suggested when the compressor operates at reduced intermittence and the total
consumption equals the compressor flow rate.
Type B installation is suggested when the air consumption can consistently change with peak values highly
exceeding the flow rate of the compressors. The capacity of the tank must be sized in order to compensate
eventual instantaneous demanding conditions (peak air consumption).
2.4 INSTALLATION LAYOUT
7
4
8
9
9
9
IN
OUT
4
5
9
6
1 Air compressor
IN
2 Final refrigerator
3 Condensate separator
OUT
5
4 Pre-Filter (min. 5 micron)
5 By-pass group
6 Dryer
6
7 Compressed air tank
8 Final filter
9 Condensate drain
7
8
9
9