Settings Menu; Define Therapy List; Personalised Therapies; Therapy Lock - Nutricia flocare Infinity III Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 58
7.4

SETTINGS MENU

7.4.1

Define therapy list

Define Therapy list controls the list of available therapies that are visible when the THERAPY [ ] button is
pressed. Therapies that are currently enabled are marked with a green switch symbol.
Personalised therapies are shown in the list of available Therapies once they have been enabled and
programmed. 2 examples are shown below.
Define therapy list
7.4.2

Personalised therapies

Personalise therapies provided the functionality to pre-program therapies that are often used.
Once programmed, it automatically appears in the list when the THERAPY [ ] button is pressed.
A personalised therapy can be created, edited or erased.
Note: Personalised therapies can be hidden using Define Therapy list.
7.4.3

Therapy lock

The THERAPY LOCK will lock an active therapy to avoid therapy tampering. It is not possible to select a new
therapy or reprogram the active therapy when the therapy lock is activated however it is possible to restart a
locked therapy. Clearing the progress bar is still possible.
A therapy lock can be activated in PAUSE mode only by pressing SETTINGS " THERAPY LOCK and a valid PIN
code must be entered. When a therapy is locked, a lock symbol appears in the status bar.
Unlocking a therapy is done via the same procedure.
Note: In case the therapy parameters need modification, consult your care giver.
7.4.4

Reset patient data

Reset patient data is designed to erase all collected patient data (non-personal)
The following data will reset:
Define therapy list, Sound settings and Display settings.
Note: The internal LOG file will not be erased, data can be recovered upon request by Nutricia or an authorised
repair centre.
7.4.5

Sound

The Flocare Infinity III supports 3 AUDIO VOLUMES, '
For safety reasons the alarm volume will be automatically escalated to
after 3 min. This safety feature cannot be turned off.
The VOLUME DELIVERED ALARM is activated by default and the pump will generate an audio and visual
warning. If it is not desired to be disturbed by the audio warning, the VOLUME DELIVERED ALARM can be
switched OFF.
Caution: Disable the VOLUME DELIVED alarm is not recommended so please consult your healthcare giver
before doing so.
Therapy list result
Therapy parameters, Progress bar, Patient history data, Personalised therapies,
Low, Medium and High'
- 13 -
Define therapy list
and can be set by the user.
High
in both settings '
Therapy list result
Low'
Medium'
and '

Publicité