2. Secure bracket into the wall stud using (2) mounting
screws or drywall anchors, as appropriate (Figure 15).
3. Secure the bracket to the floor using the screws
provided (Figure 15).
4. Later, when the unit is installed, the adjustable legs will
allow the cast base to slide under the bracket hook,
stabilizing the unit.
5. If the range is moved to a new location, the Anti-Tip
Bracket must be reinstalled.
STEP 6: Gas Requirements
and Hookup
NATURAL GAS REQUIREMENTS
Inlet Connection:
3/4'' (19 mm) NPT external
1/2'' (12.7 mm) NPT internal
(Minimum 3/4'' dia. flex line.)
Supply Pressure:
6" min. to 14" max. water
column.
(14.9 to 34.9 mb)
Manifold Pressure:
5" water column (12.5 mb)
PROPANE GAS REQUIREMENTS
Inlet Connection:
3/4'' (19 mm) NPT external
1/2'' (12.7 mm) NPT internal
(Minimum 3/4'' dia. flex line.)
Supply Pressure:
11" min. to 14" max. water
column. (27.4 mb to 34.9 mb)
Manifold Pressure:
10" water column (24.9 mb)
Installation Instructions
Figure 15: Anti-tip Bracket
Verify the type of gas being used at the installation site.
The appliance is shipped from the factory for use with
natural gas. It must be converted for use with
propane. A qualified technician or installer must do the
conversion. Make certain the range matches the type of
gas available at this location.
Natural Gas Appliances - For installation of the appliance
above 2000 ft (610 m), a High Altitude Conversion Kit
(Service Number 00746376) is available for purchase from
Thermador Customer Service. It is required that a Certified
Professional install the High Altitude Conversion Kit.
Propane (LP) Gas Appliances - The appliance must first
be converted for use with Propane (LP) Gas before it can
be converted for use at high altitude. The Propane (LP)
Conversion Kit (Service Number 00553182) supplied with
the appliance is required to be installed prior to converting
for use at high altitude. This appliance has been CSA
certified for safe operation up to an altitude of 2,000 ft (610
m) elevation above sea level. For installation of the
appliance above 2,000 ft (610 m), a High Altitude
Conversion Kit (Service Number 00746376) is available for
purchase from Thermador Customer Service. It is required
that a Certified Professional install both the Propane (LP)
Conversion Kit and the High Altitude Conversion Kit.
Hook Up
The gas supply connections shall be made by a competent
technician and in accordance with local codes or
ordinances. In the absence of local codes, the installation
must conform to the National Fuel Gas Code ANSI Z223.1/
NFPA54- current issue.
1. A manual gas shut-off valve (Figure 16) must be
installed external to the appliance, in a location
accessible from the front, for the purpose of shutting off
the gas supply. The supply line must not interfere with
the back of the unit. Make sure the gas supply is turned
off at the manual shut-off valve before connecting the
appliance.
The range is supplied with its own pressure
regulator that has been permanently mounted
within the range body.
English 16