Door Blocking System; Application With Hinged Door Icms - FRIGOGLASS ICOOL 40/150 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 71
ENG
Door Open
Temperature Reading of the Regulator Sensor.
Door Open indicator lit (stable).
If door remains open for more than d1 in Mins, it is considered as Door Open Alarm Event:
Main display toggles between the Regulator Sensor and "dOP".
Door Open indicator stays lit (stable).
If door remains open for longer than (d1+d2) in Mins, it is considered as Door Malfunctioning
Event:
Main display cycles between the Regulation Sensor, "dOP" (Door Open) and "dSF" (Door
Switch Failure).
Door Open indicator stays lit (stable).
Master Alarm indication lit (stable).
Compressor On
Compressor ON indicator lit during "ON" cycles (stable). This indicator is OΝ whenever the
compressor is On.
For instructions of the functionality of Evocool FFA1 Controller and its related optional features, please
visit the following website link: http://www.frigoglass.com/manuals/

5. Door blocking system

In using the door blocking system, please follow the steps below
5.1

Application with hinged door ICMs

To block the Door at 90 degree:
Step 1:
Open the door to an angle slightly greater than 90 degrees
Step 2:
Remove the door blocker from bracket below the door (as shown in the picture)
Step 3:
Rotate the door blocker towards the cabin and insert it in bracket located at front grid (as
shown in the picture)
To unblock the Door:
Step 1:
Open the door slightly greater than 90 degrees and remove the door blocker manually from
bracket located at front grid
Step 2:
Rotate the door blocker towards door and snap fit in bracket below the door (Initial position)
*
optional feature
16
Automatic removal of door blocker from bracket located at front grid is
for accidental purpose only.
*