Fault
During the welding operation
both straps are cutted.
After sealing and actuating
push-button 3 (66) tension
motor (504) will not turn back,
strap isn‟t released.
After sealing the tool cannot
release the strap.
TP 600
Cause
Gripper plate (78) dirty or
defective.
Tension force is too high.
Welding time too long.
If the strap cannot be freed.
Tension motor (504) dirty or
defective.
Plastic strap holding unit is
defective.
Compressed air valve defective
or error in the compressed air
system of the device.
Push-button 1 (64) has been
actuated after sealing.
If piston rod (3) is in lower
position, then the welding unit
gripper plate (24) is holding the
strap.
H TP 600 EU 37/11
Remedy
Clean gripper plate (78) or
replace it when defective, see
9.3 – 9.4
Set the correct tension force,
see 8.2
Set the correct welding time,
see 8.1
Cut off the strap from the
package and dismount the
bottom plate (77), see 9.3 to
reach the problem zone. Don't
use tools to remove the
stuck strap from the tool.
Contact TITAN – Service.
If tension motor (504) is dirty
or defective contact
TITAN – Service.
Contact TITAN – Service.
Check function of the
compressed air valve and the
compressed air system of the
device on errors. Contact
TITAN – Service.
In this case the tool is blocked,
to release the tool actuate
push-button 3 (66). Don't use
other tools to free the strap!
Cut off the strap from the
package, error is probably at
the compressed air valve
(505). Loosen carefully the
fastening screws (59) of the
compressed air valve (505) to
release pressure. Contact
TITAN – Service.