10. Troubleshooting
Fault
Strap tension insufficient
Tension and feed wheel slides
and damaging on the strap.
Seizing signs on the strap.
During tensioning strap is
braking.
During the tensioning operation
the tool rolls backwards and
strap is loose.
TP 600
Cause
Air pressure too low.
Tension motor (504) is set
incorrectly.
Pneumatic fittings and/or hoses
(88) weren‟t set correctly or
dirty.
Tension motor and/or
maintenance unit is dirty or
defective.
Compressed air valve (505) is
dirty or defective.
Tension and feed wheel (38)
and/or gripper plates were dirty
or defective.
Tension force is too high.
Use of inappropriate plastic
strap.
Use of inappropriate plastic
strap.
Tension force is too high.
Sharp packing edges.
Use of inappropriate plastic
strap.
Plastic strap holding unit is
defective.
H TP 600 EU 37/11
Remedy
Check air pressure value (min.
6 bar) and increase it if
necessary, and/or check the air
pressure system on leakage
and seal potential leakages.
Set tension motor (504)
correctly, see 8.2.
Set pneumatic fittings and/or
hoses (88) correctly and/or
clean them.
Check if tension motor and/or
maintenance unit is dirty or
defective, if it is so contact
TITAN – Service.
If compressed air valve (505) is
dirty or defective contact
TITAN – Service.
Clean tension and feed wheel
(38) and/or gripper plates and
replace them when it‟s
necessary, see 9.2 – 9.4
Set the correct tension force,
see 8.2.
Use appropriate plastic strap,
ask your TITAN – Adviser for
advice.
Use appropriate plastic strap,
ask your TITAN – Adviser for
advice.
Set the correct tension force,
see 8.2.
Use edge protectors.
Use appropriate plastic strap,
ask your TITAN – Adviser for
advice.
Contact TITAN – Service.
35