1.

Safety instructions

Target group:
For skilled electricians and
suitable qualified, instructed
personnel in accordance with national
legislation, including the relevant
standards and, where applicable, in acc.
with IEC/EN 60079-17 on electrical appara-
tus for explosive atmospheres.
– The portable searchlight must not be
used in zone 0/20 hazardous areas!
– The temperature class marked on the
portable searchlight is to be observed!
– The portable searchlight may only be
opened or charged outside of
"hazardous areas"!
– Modifications to the lamp or changes
of its design are not permitted!
– The searchlight shall only be used for
its intended purpose and in perfect
condition!
– For replacing components, only
genuine Cooper Crouse-Hinds GmbH
(CCH)/EATON spare parts may be used!
– Repairs that affect the explosion
protection, may only be carried out by
CCH/EATON or a qualified "electrician"!
– Prior to initial operation, the portable
searchlight must be charged in
accordance with the instructions
included in section 6!
– Lamps fitted with NiCd accumulators
must not be stored without a recharge
for more than 6 months!
– Pull the mains plug prior to opening
the lamp (only SEB 8 L/ SEB 8 L DIN)!
Observe the national safety rules and
regulations for prevention of accidents as
well as the following safety instructions
which are marked with an (
operating instructions!
3.

Conformity with standards

This explosion protected portable searchlight is
conform to the standards specified in the
EC-Declaration of conformity, enclosed
separately, DIN 14642 (fire brigade standard;
only SEB 8. DIN), as well as 72/245/EC and
95/54/EC EC-Type Approval Sign: e1*023025.
This portable searchlight is suitable for use in
zone 1, 21, 2 and 22 hazardous areas acc. to
IEC/EN 60079-10-1 and IEC/EN 60079-10-2.
References to standards and directives in these
operating instructions always relate to the latest
version. Other additions (e.g. details relating to
the year) shall be observed.
Explosion protected portable searchlight
SEB 8, SEB 8 L, SEB 8 ADR, SEB 8 DIN, SEB 8 L DIN
2.

Technical data

EC type sample test certificate:
Marking acc. to 2014/34/EU and standard
Lamps to be fitted
SEB 8 / SEB 8 L / SEB 8 ADR:
Main lamp (halogen lamp with double bulb):
SEB 8 DIN/SEB 8 L DIN:
Xenon-Lamp
Pilot lamp:
Rated voltage for charging
of the SEB 8 L lamp:
Duration
Main lamp:
Main beam flashlight:
Pilot light:
Battery
SEB 8/SEB 8 L/SEB 8 ADR:
SEB 8 DIN/ SEB 8 L DIN:
Indication of the charging state and capacity:
Recharge period for rated duration:
Permissible ambient temperatures
in general:
Specified data kept at battery temperature:
Storage in original packing:
Protection category to EN/IEC 60529:
Insulation class to EN/IEC 60598 during
the charging process:
with battery operation:
Geometrical data of the lamp –
Dimensions (mm):
Weight
SEB 8 L
SEB 8/SEB ADR
SEB 8 DIN
SEB 8 L DIN
4.

Description and application

There are two versions of the explosion
protected portable searchlight available.
The SEB 8/SEB 8 ADR/SEB 8 DIN searchlight
is designed for charging in the LG 443 charger
(Order No.: 1 1540 000 443) or in the motor
) in these
vehicle charger 90 (Order No.: 1 1145 000 792).
The SEB 8 L and SEB 8 L DIN seachlights
contains an additional charger unit inside of
the lamphead and can be charged useing the
built-in line cord directly at 230 V supply.
The portable searchlight is composed of two
functional units:
1. Lamphead (fig. 1)
2. Battery container (fig. 2).
The lamphead is hinged to the battery container
and can therefore be swivelled.
EN 60079-0:
BVS 08 ATEX E 116
II 2 G Ex e ib IIC T4 Gb
II 2 D Ex tb IIIC T85°C Db
5.5 V / 5.5 W BA 15 d cap
Order No.: 1 2061 000 040
4.8 V / 4 W, BA 15 d cap
Order No.: 1 2061 001 400
4.8 V / 1.5 W, BA 9s cap
Order No.: 1 2041 000 450
230 – 250 V +/- 10%, 50/60 Hz
(with integrated charging connection)
approx. 5.5 h
approx. 23 h
approx. 22 h
4 NC- 4.8 V 7 AH (only type 2 1147 701 000)
4 NC- 4.8 V 5 AH (only type 2 1147 512 000)
see fig. 3 and 4
up to 14 h, dependent on the residual capacity
-20°C to +40°C
-5°C to +30°C
-20°C to +40°C
IP 65
II
III
see fig. 7
approx. 2.5 kg
approx. 2.0 kg
approx. 1.6 kg (without accessoires)
approx. 2.2 kg (without accessoires)
A rotary switch (fig. 1, item 1) with 5 switch
positions is arranged below the carrying handle.
= service
= pilot light (bypass)
0
= OFF
= main beam
= flashing main beam
An LED indicating the charging state and
capacity (page 2, fig. 1, item 2) is laterally
arranged on the lamphead.
A swivelling pocket containing the slip-on filters
is locked in on the back of the lamphead
(page 2, fig. 1, item 3/5).
By turning the pocket, the charging lead is
accessible (page 2, fig. 1, item 4).
Max. three slip-on filters (diffusing lenses) can
be kept in the pocket.
For safe transportation in areas with
explosive atmosphere, which in shims in the
insert disc container or in the holder of the
bolting keep.