CASTLE Serenity Manuel De L'utilisateur page 27

Masquer les pouces Voir aussi pour Serenity:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SETTING THE TEMPERATURE UNITS
1. Press and hold the ENTER button. This will take you to the
"Set Data" screen.
2. Using the SCROLL DOWN key, move down to option 3: "Set
Temperature Units". Press ENTER again to move into the "Set
Temperature Units" screen. SEE FIGURE 25.
3. In the set temperature units menu, press the ENTER button to
highlight the units. Use the SCROLL UP and SCROLL DOWN
buttons to choose either Celsius (C°) or Fahrenheit (F°).
4. When finished, press ENTER. With nothing highlighted on the
screen, press the EXIT button.
Set Temperature Units
Temperature Units: C°
Figure 25
SETTING THE BLOWER VOLTAGE
The blower voltage (controlling the room fan) can be turned
up or down for each power level to regulate the amount of
heat circulated into a room during stove operation. Some fuels
radiate heat better than others. You have the ability to speed
up or slow down the room fan to extract the optimum amount
of heat without blowing cold air.
Increasing the blower voltage causes the convection motor to
run faster, extracting more heat from the unit.
NOTE: If having issues with the stove overtemping in any
setting, increase the blower voltage.
Decreasing the blower voltage allows you to slow the exchange
of heat from the stove so it blows less cold air.
Check for parts online at www.castlestoves.com or call 800-345-6007 M-F 8-5 CST
All manuals and user guides at all-guides.com
To set the blower voltage:
1. Press and hold the ENTER button. This will take you to the
2. Using the SCROLL DOWN key, move down to option 4: "Set
3. Select the stall (or heating power level) for the voltage you'd
4. Using the SCROLL UP or SCROLL DOWN keys, select the
5. Press ENTER to finalize your changes. Repeat steps 2-4 for
Figure 26
"Set Data" screen.
Blower Voltage". Press ENTER again to move into the "Set
Blower Voltage" screen. SEE FIGURE 26.
like to change by scrolling up or down and pressing ENTER.
The voltage amount will automatically be highlighted.
appropriate voltage. NOTE: Voltage can be decreased or
increased only in increments of five (5).
the other stalls if you so desire.
Set Blower Voltage
1.Stall1 Voltage:~85V
2.Stall2 Voltage:~90V
3.Stall3 Voltage:~95V
4.Stall4 Voltage:~100V
5.Stall5 Voltage:~110V
Operator's Manual
Serenity Pellet Stove
27

Publicité

Chapitres

Table des Matières
loading

Produits Connexes pour CASTLE Serenity

Table des Matières