Venting the Pellet Stove:
• Do not install flue damper in the exhaust venting system
of this unit.
• Use an approved wall thimble when passing the vent
through walls. Use a ceiling support/fire stop spacer when
passing the vent through ceilings (make sure to maintain
clearance to any combustibles.)
• if using more than one tee and 180
use 4" venting pipes.
NOTE: In order to achieve optimum performance, it is
recommended that you keep the vent as short as possible,
especially in regards to the horizontal run.
The vent must have a support bracket every 5' of pellet vent
when on the exterior of the structure.
The vent height and run must not exceed the distance as
illustrated in the diagram below.
Venting into this (the lighter) shaded area may require
combustion motor voltage adjustments and/or inlet air
adjustments (intake). SEE FIGURE 9.
INTAKE & EXHAUST POSITIONS
Figure 8: Intake and exhaust positions
14
All manuals and user guides at all-guides.com
of elbows, you must
o
Figure 9: Venting and combustion motor voltage adjustment chart
Check for parts online at www.castlestoves.com or call 800-345-6007 M-F 8-5 CST
Operator's Manual
Serenity Pellet Stove
33 Feet
(max.)
30 Feet
25 Feet
20 Feet
15 Feet
10 Feet
5 Feet
0 Feet