OPERATION

After you have chosen the mode in which to operate your stove,
press the ON/OFF button
START UP
When the stove turns on, the ignition indicator and the
combustion blower indicator will appear on the screen (images
7 and 8 in Figure 19 on page 23). "Ignite" will also appear in the
work stage box on the screen. After approximately four seconds,
the vacuum switch indicator will appear. Also note that the
hopper lid open indicator (limit indicator) will appear anytime
the stove's hopper lid is properly shut and sealed.
The stove motor will continue to run for three minutes, then the
auger indicator will flash on the screen, indicating that the auger
is feeding pellets into the stove. Within three to five minutes of
the auger feeding pellets, a fire should ignite. Once a fire is lit,
the work stage box on the screen will read "Heating Room".
WORKING IN THE DIFFERENT OPERATION MODES
MANUAL MODE
The Manual Mode is the default mode setting if no other mode is
chosen before the stove is turned on. In the manual mode, you have
the ability to change the heat levels, which will increase or decrease
the amount of heat that the stove puts out.
To change the power level in manual mode, use the SCROLL DOWN
or SCROLL UP buttons on the control pad. (See buttons
8 and 10 on Figure 17.) Pressing either of these buttons once will
move the power level up or down one level.
NOTE: This mode does not allow you to directly adjust
specific temperatures. The manual mode simply allows you
to dictate the level of heat the stove is pushing out.
THERMOSTAT/TEMPERATURE CONTROL MODE
The Thermostat Mode allows you to set the temperature of the
room. The stove will increase or decrease the level of heat it
puts out automatically to keep the room at the set temperature.
To increase or decrease the "call to" temperature, use the SCROLL
UP or SCROLL DOWN button. The current room temperature will
be displayed in the temperature display box on the screen, as
will the "call to" temperature.
Check for parts online at www.castlestoves.com or call 800-345-6007 M-F 8-5 CST
All manuals and user guides at all-guides.com
to start the stove ignite cycle.
WARNING
NEVER SHUT THE STOVE DOWN BY UNPLUGGING IT
FROM THE POWER SOURCE.
NEVER SHUT THE STOVE DOWN BY SWITCHING OFF
THE MAIN POWER SWITCH ON THE REAR OF THE
STOVE.
NEVER OPEN SIDE PANELS OR MAIN DOOR WHEN
STOVE IS IN OPERATION.
NEVER TOUCH GLASS DOOR AND ASH PAN LATCHES
WHILE IN OPERATION, THEY GET EXTREMELY HOT
AND WILL BURN YOU.
If the room temperature falls below the " call to" temperature, the
stove's heat power level indicator will automatically rise to five.
When the temperature has been reached, the heat power level
will return to one and it will stay there until more heat is needed.
Note: In thermostat mode, the stove will not go into
standby. It will simply idle and continue to produce a fire
until the room is no longer at the set "call to" temperature.
When it is idling, the stove will read at power level one in
the power level box on the display screen.
WEEKLY MODE
The Weekly Mode allows an Serenity user to control and schedule
the stove operation during set times and days throughout the
week. You can select four different operation times for each of
the seven days of the week.
IMPORTANT: Remember to set your weekly schedule in Weekly
Mode before igniting a fire. If you try to set the stove schedule
and weekly mode while running in Manual or Thermostat
modes, the weekly schedule will not set, and the screen will
prompt you to wait until you have turned the stove off and it
has cooled down before setting the schedule.
To Set Weekly Schedule:
1. Press and hold the ENTER button until the "Set Data"
menu appears on the screen. Using the SCROLL DOWN
button, select "Set Weekly. " Press ENTER. This will take you
into the "Weekly Schedule" screen. SEE FIGURE 22.
SET DATA
1. Set Clock
2. Set Weekly
3. Set Temperature Units
4. Set Blower Voltage
Figure 22