1 flash every 5 seconds
Series of flashes separated
by a pause
Fast flashing
LED STOP [B]
Off
On
LED SbS [C]
Off
On
LED P1 [D]
Off *
On
Series of quick flashes,
from 1 to 4
5 quick flashes
1 slow flash
3 slow flashes
5 slow flashes
LED P2 [E]
Off *
On
1 flash per second
2 flashes per second
LED P3 [F]
Off *
On
1 slow flash
2 slow flashes
* or it could be in "Standby" mode
––– STEP 10 –––
The maintenance operations must be performed in strict com-
pliance with the safety directions provided in this manual and
according to the applicable legislation and standards.
The automation devices do not require special maintenance operations;
however periodically check, at least once every six months, the perfect
This product is an integral part of the automation system it con-
trols and must be disposed of along with it.
As with installation operations, disposal operations must be performed by
qualified personnel at the end of the product's useful life.
This product is made of various types of materials, some of which can be
recycled while others must be scrapped. Seek information on the recy-
cling and disposal systems required by local regulations in your area for
this product category.
Caution! – some parts of the product may contain pollutants or hazard-
28 – English
Automation in "standby" mode
This is the same signal as on the flasher, see Table 12
ECSbus short circuit
Status
Activation of the STOP input
Everything OK
Status
Everything OK
SbS input activation
Status
All OK
Memorisation in Mode 1
Memorisation in Mode 2
Cancellation OK
Cancellation OK
Memorisation OK
Cancellation OK
Status
All OK
All OK
The device recognition phase has
not been carried out, or there are
errors in the data saved
Devices recognition phase in pro-
gress
Status
All OK
Everything OK
There is no memorised opening
angle
Opening angles recognition phase
in progress

MAINTENANCE

DISPOSAL OF THE PRODUCT
All OK; when a command arrives, the control unit will reset to normal func-
tioning (after a brief delay).
An overload has been detected and therefore the power supply to the ECSbus
has been turned off. Check, possibly by disconnecting each device one at a time.
To switch on power to the ECSbus you simply need to give the command, for
example, using the radio transmitter
Action
Check the devices connected to the STOP input
STOP Input active.
Action
SbS input not active
Normal only if the device connected to the SbS input is active
Action
No memorisation in progress.
During memorisation in mode 1, it is normal for it to take a maximum of 10 s.
During memorisation in mode 2, it is normal for it to take a maximum of 10 s.
Completion of deletion of a transmitter.
A command has been received from an unmemorised transmitter
Memorisation completed successfully
Completion of deletion of all transmitters.
Action
"Slow" speed selected
"Fast" speed selected
It is possible that there are faulty devices. Check and if necessary repeat
the device recognition phase (see paragraph 9.3.3 "Recognition of other
devices").
Indicates that it is in the process of recognising the attached devices (this will
take a maximum of a few seconds).
Action
Cycle operation
Complete cycle operation
Carry out the recognition phase (see Chapter 3.5.2 - Leaf open and closure
angles recognition)
Indicates that the open angles self-learning phase is in progress
efficiency of all the devices.
For this purpose, to perform all the tests and checks provided for in para-
graph 8.1 "Testing" and carried out as provided for in paragraph "User-
admissible maintenance operations".
If other devices are present, follow the steps as laid out in the relevant
maintenance schedule.
ous substances which, if released into the environment, may cause seri-
ous damage to the environment or human health.
As indicated by the symbol on the side, disposal of this
product as domestic waste is strictly prohibited. Separate
waste into categories for disposal, according to the meth-
ods established by local regulations, or return the product
to the retailer when purchasing a new version.
Caution! – Local legislation may envisage serious fines in
the event of abusive disposal of this product.

Publicité