Installation

Before You Begin

Tools and Parts Needed

1. Phillips Head Screwdriver
2. Drill with 1/4" (6.5mm) bit
3. Tape Measure
4. Teflon Tape (Gas Rated)
5. Adjustable wrench or channel lock pliers

Parts Included

1. Foam tape
2. Hold down brackets (4)
3. Screws, #10-32 x 2 1/2" (63.8mm) (4)
4. Sheet Metal Screws, #8 x 3/8" (9.5mm) (4)
5. Washers (4)
6. Burner Grates (3)
7. Burner Caps
36" models: (5)
30" models: (4) or (5)
8. Pressure Regulator
9. LP Gas Conversion Kit
If parts are missing or damaged, call the number or write to
the address listed inside the back cover.

General Information

Overall Dimensions
30" Models
Width
31" (788 mm)
(Side to Side)
Depth
21 1/4" (540
(Front to Back)
mm)
Height
3 13/16 (97 mm)
(Top to Bottom)
NOTE:
These are overall dimensions NOT cutout dimensions.

Preparation

Electrical Requirements
9 CAUTION
This appliances requires a 60 Hz, 15 Amp, 120 VAC
connection. Plan the installation so that the power
connection is accessible from the front of the cabinet.
Gas Requirements
Supply Pressure:
The propane gas tank must be equipped with its own high
pressure regulator in addition to the pressure regulator
supplied with this unit. The cooktop is shipped from the
factory for use with natural gas. For use with LP conversion
a qualified technician or installer must do the conversion.
Cabinet Requirements
Dimension requirements in Figures 1 and 2 are for
combustible surfaces. When the surface is protected by a
material listed by UL as a Floor Protector and Wall Shield
covered with not less than No. 28 MSG sheet metal 0.015
inch (0.38mm) stainless steel, 0.024 inch (0.6mm)
aluminum or copper, it is considered noncombustible and
some dimensions may be reduced. For a noncombustible
36" Models
surface over the cooktop, the minimum clearance is 24"
37" (940 mm)
(61cm) rather than 30" (76cm).
21 1/4" (540
mm)
3 13/16 (97 mm)
Do not use an extension cord with the gas cooktop.
Natural Gas - 7 inches water column (14.9 Millibars)
minimum.
Propane Gas -11 inches water column (27.4 Millibars)
minimum.
Instructions are based on standard American cabinets
36" high (91cm) x 24" deep (61cm) with a 25" (63cm)
countertop.
Provide approximately a 10 square inch opening
2
) in the toe kick area or other cabinet area for
(65cm
adequate air inlet to the cabinet if installed with a
downdraft.
English 3