11 Technical data

11.1 General

Constructed from aluminium
Epoxypolyester powder painting, RAL9002 colour
Stainless steel external screws

11.2 Mechanical

Cable glands: 3xM16
Housing window
• Dimensions (WxH): 94x80mm (3.7x3.1in)
• Material: Glass
Internal usable area
• Empty version: 134x88mm (5.1x3.5in)
• Version with double or triple heater : 112x88mm
(in)
Internal usable length (without accessories)
• HEG37: 365mm (in)
• HEG47: 450mm (in)
Internal usable length (with accessories):
• HEG37: 273mm (10.7in)
• HEG47: 363mm (in)
Unit weight
• HEG37: 4.1kg (9lb)
• HEG47: 4.7kg (10.3lb)

11.3 Electrical

Power supply/Current consumption (version with
heater, Ton 15°C±3°C (59°F ±5°F), Toff 22°C±3°C
(77°F±5°F)):
• 12Vdc, 1.6A max
• 24Vac, 0.85A max, 50/60Hz
• 120Vac, 0.35A max, 50/60Hz
• 230Vac, 0.18A max, 50/60Hz
Power supply/Current consumption (version with
double heater, Ton 15°C±3°C (59°F ±5°F), Toff
22°C±3°C (77°F±5°F)):
• 120Vac, 0.7A max, 50/60Hz
• 230Vac, 0.35A max, 50/60Hz
MNVCHEG_1511_EN
Power supply/Current consumption (version with
triple heater, continuous duty fan , Ton 15°C±3°C
(59°F ±5°F), Toff 22°C±3°C (77°F±5°F)):
• 120Vac, 1A max, 50/60Hz
• 230Vac, 0.52A max, 50/60Hz
Power supply/Current consumption (version with
blower and thermostat for models with double
filter for air renewal, Ton 35°C±3°C (95°F±5°F), Toff
20°C±3°C (71°F±5°F)):
• 12Vdc, 0.33A max
• 24Vac, 0.16A max, 50/60Hz
Camera power supply:
• V
from 100Vac a 240Vac, 50/60Hz
IN
V
12Vdc, 1A
OUT
• V
230Vac, 50/60Hz
IN
V
24Vac, 400mA, 50/60Hz
OUT

11.4 Environment

Indoor/Outdoor
Operating temperature
• Version with heater: From -20°C (-4°F) a +60°C
(140°F)
• Version with double heater: From -40°C (-40°F) a
+60°C (140°F)
• Version with triple heater, continuous duty fan:
From -50°C (-58°F) a +60°C (140°F)

11.5 Certifications

Electrical safety (CE): EN60065
Electromagnetic compatibility (CE): EN50130-4,
EN61000-6-3
IP protection degree:
• EN60529, IP66/IP67 (with cable glands)
• EN60529, IP44 (with double filter for air renewal)
Salty fog resistance: ISO9227, to 1000 hours
EAC certification
9