10 Technical data

10.1 Mechanical

Non-corrosive die-cast aluminium (anticorodal)
Epoxy powder painted, RAL9002
Cable entry: 2 holes, 3/4" NPT
Internal dimensions: Ø 180x380mm (7.1x15in)
Internal usable dimensions: 100x100x280mm
(3.9x3.9x11in)
Unit weight:
• 15kg (33.5lb)

10.2 Housing's window

Window with extra clear tempered glass
• Usable diameter: 114mm (4.5in)
• Thick: 12mm (0.47in)
Germanium window
• Usable diameter: 114mm (4.5in)
• Thick: 11mm (0.43in)
• External treatment: antiscratch (Hard Carbon
Coating - DLC), antireflection
• Internal treatment: antireflection
• Spectral range: from 7.5μm up to 14μm
• Medium transmittance (from 7.5μm up to
11.5μm): 87.5%
• Medium transmittance (from 11.5μm up to 14μm):
72.1%

10.3 Electrical

Supply voltage/Current consumption (Ton 15°C±4°C
(59°F±7°F), Toff 22°C±3°C (72°F±5°F)):
• 230Vac, 0.3A, 50/60Hz
• 24Vac, 2.5A, 50/60Hz
Power consumption
• Heater: 60W
• Installable camera: 20W max
18

10.4 Environment

For indoors and outdoors installation
Operating temperature with heating: from-40°C
(-40°F) up to +50°C (122°F)
Relative humidity: from 5% up to 95%
10.5 Certifications and
compliances
Electrical safety (CE): EN62368-1
Electromagnetic compatibility (CE): EN61000-6-3,
EN61000-3-2, EN61000-3-3, EN50130-4, EN55032
(Class B)
RoHS (CE): EN IEC 63000
Outdoor installation (CE): EN60950-22, IEC60950-22
IP protection degree (EN/IEC60529): IP66
10.6 Certifications - Explosion-
proof applications
ATEX (EN IEC 60079-0, EN 60079-1, EN 60079-31)
IECEx (IEC 60079-0, IEC 60079-1, IEC 60079-31)
EAC Ex (TR CU 012/2011)
For further details on certifications and markings, consult the relevant
table.