7 Maintenance
Before carrying out any type of
intervention, read the "Safety rules"
chapter of this manual.
When contacting VIDEOTEC for assistance please
provide the serial number and the identification code
of the model.
7.1 Routine maintenance
Frequency will depend on the type of
environment in which the product is used.
7.1.1 Inspecting the cables
The cables should not show signs of damage or wear,
which could generate hazardous situations. In this
case extraordinary maintenance is necessary.
7.1.2 Replacing the gasket
In the event of o-ring gasket deterioration replace
it using the gasket supplied. Use only VIDEOTEC
original spare parts.
Replace the gasket of the product with the one
supplied.
Open and close the rear flange as described in the
chapters above.
Replace the gasket, paying attention to position it
correctly.
Fig. 12
16
7.2 Extraordinary maintenance
7.2.1 Fuse replacement
CAUTION! For continued protection against
risk of fire, replace only with same type and
rating of fuse. Fuses must be replaced only
by service personnel.
The new fuse must comply with the directions given
in the table.
FUSE REPLACEMENT
Supply voltage
24Vac
230Vac
Tab. 5
Fuse
F 1.6A L 250V 5x20
MNVCEXH_2104_EN