Maintaining And Cleaning; Window And Plastic Cover Cleaning; Disposal Of Waste Materials; Technical Data - Videotec MEDUSA Mode D'emploi

Masquer les pouces Voir aussi pour MEDUSA:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7  Maintaining and cleaning
7.1 Window and plastic cover
cleaning
Wash with neutral soap and water.
Avoid ethyl alcohol, solvents, hydrogenated
h
g
hydrocarbide, strong acid and alkali. Such
products may irreparably damage the
plastic surfaces.
8  Disposal of waste 
materials
This symbol mark and recycle system
n
g
are applied only to EU countries and not
applied to the countries in the other area of
the world.
Your product is designed and manufactured with
high quality materials and components which can be
recycled and reused.
This symbol means that electrical and electronic
equipment, at their end-of-life, should be disposed of
separately from your household waste.
Please dispose of this equipment at your local
Community waste collection or Recycling centre.
In the European Union there are separate collection
systems for used electrical and electronic products.
10
9  Technical data

9.1 General

Constructed from die-cast aluminium
Epoxypolyester powder painting, RAL9002 colour
Lower semisphere: in PMMA transparent or smoked (in
this case the loss of luminosity is 1 lux)
Sunshield in ABS for outdoor, RAL9002 colour
Supplied with instruction manual, cable glands and
protection gasket

9.2 Mechanical

External dimensions with sunshield: Ø 351x335mm
(13.8x13.2in)
External dimensions without sunshield: Ø 314x322mm
(12.4x12.7in)
4 cable-glands: 3xM16 allowing Ø cable 3,5-7mm (0.1-
0.3in), 1xM12 allowing Ø cable 5-10mm (0.2-0.4in)
Unit weight: 4.2kg / 9.3lb (without camera adapter)

9.3 Electrical

Fan assisted heater, Ton 15°C ±3°C (59°F ±37°F) Toff
22°C ±3°C (71°F ±37°F)
- IN 24Vac, consumption 24W max
- IN 100/240Vac, consumption 44W max
Camera power supply included with internal adapter
- IN 100/240Vac, 50/60Hz, OUT 12Vdc, 3A max
- IN 100/240Vac, 50-60Hz, OUT 24Vdc, 1.5A max
- IN 230Vac, 50/60Hz, OUT 24Vac, 2A max
- IN 24Vac/24Vdc, 50/60Hz, OUT 12Vdc, 2A max
Blower in continuous duty for heater assistance Ton
15°C ±3°C (59°F ±37°F) Toff 22°C ±3°C (71°F ±37°F)
- IN 12Vdc, consumption 4W max
Blower for air-exchange with thermostat Ton
35°C±3°C (95°F ±37°F) Toff 20°C±3°C (68°F ±37°F)
- IN 12Vdc, consumption 4W max

9.4 Environment

Indoor / Outdoor
Operating temperature with standard fan-assisted
heater: -20°C / +60°C (-4°F / +140°F)
Operating temperature with reinforced heater kit (to be
installed only with adapters ODBH18H series and only
with camera and lens options guaranteed to work in
operating temperatures down to -10° (14F°): from -30°C
to +50°C (from -22°F to +122°F)

9.5 Certifications

CE EN61000-6-3, EN60950-1, EN50130-4
IP66 EN60529
IP44 EN60529 for models with cooling blower and
double filter