3.4 Installation of water system

INTERNAL PUMP (OPTIONAL)
1)
Use the pipe a (900 mm, provided with the machine) to connect the cut-off valve of the mains to the tap
1 for water inlet to the water softener (figure 3).
2)
Connect the pipe b for internal pump suction to the tap 2 of the water softener (figure 4).
a
Figure 3
EXTERNAL PUMP
Use the pipe a (900 mm, provided with the machine) to connect the cut-off valve of the mains to the tap
1)
1 for water inlet to the water softener (figure 5).
2)
Connect pipe c (600 mm, provided with the external pump) to the pump suction with tap 2 of the water
softener (figures 6-7).
3)
Connect pipe d (of the water system of the coffee machine) to the pump delivery (figure 7).
a
Figure 5

3.5 Drain line

Connect the drainage tube to the grounds collecting tray and to the water drainage system.

3.6 Electrical connection

Instructions for a proper electrical connection of the espresso coffee machine:
• Before connecting the unit to the electrical mains, make sure that the data on the data
plate corresponds to the electrical mains.
• The tag is located on the left side of the machine (and can be accessed by removing the
lower tray).
• The electrical system provided by the client must comply with current standards. The
power socket must be equipped with a working earth connection. LA SAN MARCO
SPA will not in any way be held liable if legal requirements are not met. An improper in-
stallation can cause injury or damage for which the manufacturer cannot be held liable.
• For the electrical connection, it is necessary to install an omnipolar main switch up-
stream of the power supply; this switch should be rated according to the electrical
characteristics (power and voltage) shown on the rating tag. The omnipolar switch must
disconnect the power supply with a contact gap of at least 3 mm.
• If it is necessary to use adapters, multiple plugs and extensions, only products meeting
applicable safety standards must be used.
• To avoid any overheating of the power cable, unwind it completely.
Connect the power cord to the electrical mains as shown in the attached diagram:
44
1
Figure 4
1
b
Figure 6
b
2
d
2
Figure 7
c