Ingeteam INGEREV CITY CW116 Manuel D'installation Et Usage page 51

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operation
Connection type
CEE 7/7 (Schuko)
IEC 62196-2 type 2
IEC 62196-2 type 3A
The station does not allow, nor is it designed for simultaneous use of both sockets. Only the selected
socked is enabled.
Once the vehicle is detected at the station, it proceeds to block the cover and start supplying energy, going to a
charging status.
Ending the charge process
4.
To finish the charge cycle identify the card using the reader. The station interrupts the electrical supply
and unlocks the cover of the receptacle or the connector.
5.
Open the cover, pull out the connector and close the cover. The station will lock the cover and return to
the awaiting vehicle status.
Loss of power
The station has an auxiliary supply (INGEREV CITY models) that allows basic operations to be carried out when
faced with a loss of electricity supply. In such a situation the station indicates this anomaly on the display.
In the event that the station is in the awaiting vehicle status and the electricity supply is lost, the message shown
is:
If the supply loss occurs when a vehicle is being charged, the message is:
In this situation the user must identify the ID card using the reader again to unlock the cover and disconnect the
vehicle. When this is complete the station shuts down.
A Master User can unlock the cover to pull out the connector and, after identifying themselves, can
shut down the station with the lock active.
When supply is restored after the supply is lost, the station returns to the status active before said loss of supply.
9.2.2. INGEREV CITY Duo
The electrical supply connector must not be removed from the vehicle while the charging is being
carried out.
Starting the charge process
1.
Check that at least one of the Sockets is in vehicle standby position, lit in steady green.
ABA2020IQM01_A - Installation and Operation Manual
Connection detection
Automatic detection after lowering the
cover
Instant automatic detection
Instant automatic detection
"AC FAILURE"
"AC FAILURE. Identify again to unlock the door"
Ingeteam
Regulation governing the charge
sequence
IEC61851
IEC61851
IEC61851
EN
ES
FR
IT
51