Repairs on the unit
4
3
1
6
2
11.4
PRESSURE REGULATING VALVE (FIG. 22, ITEM 1)
Allow pressure regulating valve (1) only to be
replaced by the customer service. The max.
operating pressure is to be reset by the cus-
tomer service.
Attention
11.5
RELIEF VALVE
Switch off unit
Pull mains plug from socket before repair.
Danger
1. Screw out stop screw (2) from the regulating knob (fig. 23,
item 1) into switch position
2. Remove regulating knob.
40
5
1
(OFF).
(spray).
GB
3. Screw out screws (fig. 24, item 3) from the switch housing
(4).
4. Remove switch housing (4) from the paint section.
5. Screw relief valve (5) out with the spanner 17mm.
6. Clean valve seat with cleaning agent and brush.
7. Check O-ring (6) for damage, replace if necessary.
6
5
Mounting regulating knob (fig. 23, item 1).
1. Place regulating knob first of all onto the axle, turn a little
until the regulating knob can be pushed on completely.
2. Turn regulating knob into switch position
this position can the stop screw (fig. 23, item 2) be pushed
in by hand and screwed tight.
!
1
2
4
3
3
(spray). Only in
Super Finish 27 • 31