Outlet Valve; Pressure Control Valve - WAGNER SUPER FINISH 33 PRO Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Super Finish 33 PRO
10.3

OUTLET VALVE

1. Use a 22 mm wrench to screw the outlet valve from the
paint section.
2. Carefully pull of the clasp (1) using the enclosed screw-
driver. The compression spring (2) presses ball (4) and
valve seat (5) out.
3. Clean or replace the components.
4. Check the O-ring (7) for damage.
5. Check the installation position when mounting the spring
support ring (3) (clipped onto spring (2)), outlet valve seat
(5) and seal (6), refer to figure.
The torque for fitting the outlet valve is 50 Nm.
2
1
7
6
5
3 4
10.4

PRESSURE CONTROL VALVE

Only have the pressure control valve (1) re-
placed by the customer service.
The max. operating pressure has to be reset
by the customer service.
1
GB
REPAIRS AT THE UNIT
53