Outlet Valve; Pressure Regulating Valve; Relief Valve - WAGNER Super Finish 21 Mode D'emploi

Masquer les pouces Voir aussi pour Super Finish 21:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

11.2 Outlet valve (fig. 21)
1. Screw out outlet valve with spanner 22 mm
from the paint section.
2. Remove clasp (1) carefully with screw-
driver, pressure spring (2) presses parts
out 3 to 4.
Attention
3. Clean or replace individual parts.
4. Check O-ring (6) for damage.
5. Pay attention to installation position in mounting
spring support ring (3), outlet valve seat (4) and
seal ring (5).
1
3
4
6
2
11.3 Pressure regulating valve (fig. 22,
item 1)
Allow pressure regulating valve (1) only to
be replaced by the customer service.
The max. operating pressure is to be re-
Attention
set by the customer service.
Super Finish 21 • 23
All manuals and user guides at all-guides.com
g
g
11.4 Relief valve (fig. 23)
5
Switch off unit.
Pull mains plug from the socket before
all repairs.
Danger
1. Screw relief valve (1) out with the spanner
17 mm.
2. Clean valve seat with cleaning agent and brush.
3. Check O-ring (2) for damage, replace if
necessary.
Repairs on the unit
1
2
1