Appendix 1: Technical Data - Dovre 2020 Installation Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 88

Appendix 1: Technical data

Model 2200 / 2210 / 2220 / 2320 / 2020 / 2120
Model
Nominal output
Flue connection (diameter)
Weight
Recommended fuel
Fuel property, max. length wood
Electrical connection
Fuel
Mass flow of flue gasses
Temperature increase measured in the
measuring section
Temperature measured at appliance exit
Minimum draught
CO emission (13%O
)
2
NOx emission (13% O
)
2
CnHm emission (13%O
)
2
Particulate emission
Efficiency
Subject to change because of technical improvements
2200
2210
8 kW
8 kW
150 mm
150 mm
140 kg
175 kg
Wood
Wood
50 cm
50 cm
230 V, 50 Hz, 0.5 A
Brown coal bri-
Wood
quettes
7.7 g/s
8.9 g/s
295 K
289 K
340 °C
-
14 Pa
14 Pa
0.10 %
0.06 %
106 mg/Nm³
-
51 mg/Nm³
-
31 mg/Nm³
-
78.3 %
75.4 %
2220 / 2320
2020 / 2120
8 kW
7 kW
150 mm
150 mm
150 kg
130 kg
Wood
Wood
50 cm
40 cm
Anthracite coal
7.8 g/s
272 K
-
14 Pa
0.04 %
-
-
-
76.4 %
23