Appendix 1: Technical Data - Dovre 2175CBS Installation Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 54

Appendix 1: Technical Data

Model
Rated output
Chimney connection (diameter)
Weight
Recommended fuel
Fuel property, max. length
Flue gas flow rate
Temperature rise measured in the measuring section
Temperature measured at the appliance outlet
Minimum draught
CO emission (13%O
)
2
NOx emission (13% O
)
2
CnHm emission (13%O
)
2
Particulate emission
Particulate emission to NS3058-NS3059
Efficiency
Subject to change because of technical improvements
Series 2170CB and 2570CB
10 kW
150 mm
+/- 160 kg
Wood
50 cm
10.1 g/s
260 K
345 °C
12 Pa
0,06 %
118 mg/Nm³
70 mg/Nm³
19 mg/Nm³
7.1 g/kg
75,9 %