Service

During cleaning and service of the unit, the unit should
be disconnected from the power supply.
The fine filter should be changed at least once per
year. Use only original parts for replacement. If the
unit is equipped with a HEPA filter, this filter should
be changed every 300 working hours. Use breathing
protection and perform this operation in a contained
area. The used filter should be placed in containment
and disposed of in the proper and prescribed method.
Filter change:
Remove the motor head. Lift the filter straight up out
of the cyclone. When required, a plastic sack can be
placed over the cyclone for dust-free filter change.
The filter is lifted directly into the sack.
During the filter change, check the filter gasket. A
damaged gasket can allow the release of hazardous
dust. Never use old gaskets or after-market filters.
Use only genuine Dustcontrol spare parts to maintain
the unit for use on hazardous dusts.
Check regularly that the electrical cable is not dama-
ged. The DC 2800c should be performance tested at
least once per year because it may be used with
hazardous materials. Worn parts must be replaced.
The vacuum motor is maintenance free.
DC 2800c, 11
Art nr 9453