Test Running

Check that the vacuum producer is correctly installed and
inlet and outlet connected to the duct system. Th e tubing
between the fi lter unit and vacuum producer must be free
from particles. Objects in the vacuum producer can cause
failure.
Check discharge arrangement. No leakage can be al-
lowed.

Service

If the system does not give full suction after fi lter clea-
ning, it is recommended that the fi ne fi lters are changed.
Use only original fi lters.
Th e condition of the fi lters can be checked by measuring
the pressure drop over the cleaned fi lters with a mano-

Filterchange

Th e fi lters should be changed at least once per year. Only
original fi lter is allowed. Use breathing protection during
the fi lter change. Do not expose unprotected persons to
harmful dust.
-
Turn off and lock the disconnect of the vacuum
producer.
-
Use breathing protection.
-
Lift off the top of the fi lter unit.
-
Lift out the fi lters and seal them in a plastic sack.
-
Lift in the new fi lters, and connect the top.
If the extracted dust is collected in a plastic bag, the bag
should be changed when the dust level is 5 cm under the
plastic fl ap at the bottom of the fi lter unit. Th e plastic
sack must be sealed when removed from the fi lter unit.
If the dust is collected in a container, it should be chan-
ged or emptied before it is completely full.
2015-01-28
S 11000 - EX, S 21000 - EX, S 32000, S 34000 - EX, S 46000 - 28
Cleaning of the fi lters
Th e fi lters of the dust separator are cleaned automatically.
Th is is done at diff erent times, depending on
confi guration of the system.
When the fi lter is cleaned a number of very clear air pul-
ses, with a few seconds interval, should be heared.
meter (Part No 8283). If the manometer registers a value
higher than 3 - 4 kPa the fi lters should be changed.
Some time after the installation there should be a follow-
up check on all screws and nuts.
Filter Part No
S 11000
4292
S 11000 EX
429206
S 21000
4284
S 21000 EX
429206
S 32000
4292
S 34000
4292
S 34000X
4284
S 34000 EX
429206
S 46000
4284
Number
1
1
1
1
2
4
4
4
6
Part No 94160-B

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

S 21000 - exS 32000S 34000 - exS 4600094160-b

Table des Matières